background image

7

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

1.5  HYDRAULIC CONNECTION.

Attention:

 before connecting the water heater 

and so as not to make the warranty null and void 

on the DHW heat exchanger, wash the system 

thoroughly (piping, etc.) in a way to remove 

any residue that could compromise the good 

functioning of the water heater.
Water connections must be made in a rational 

way using the couplings on the water heater 

template.

Attention:

 to preserve the duration and features 

of appliance efficiency, in the presence of water 

whose features can lead to the deposit of lime 

scale, it is necessary to install the “polyphosphate 

dispenser” kit.

If the network fuse on the connection terminal 

block needs replacing, this must also be done by 

qualified personnel: use a 3.15 A fast fuse. For 

the main power supply to the appliance, never 

use adapters, multiple sockets or extension leads.

N.B.: 

all water heater pipes must never be used 

to earth the electric or telephone lines. Ensure 

elimination of this risk before making the water 

heater electrical connections.

1.6  ELECTRICAL CONNECTION.

The “Caesar Eco” water heater has an IPX5D pro-

tection rating for the entire appliance. Electrical 

safety of the appliance is reached only when it 

is correctly connected to an efficient earthing 

system as specified by current safety standards.

Attention:

 the manufacturer declines any 

responsibility for damage or physical injury 

caused by failure to connect the water heater to 

an efficient earth system or failure to comply with 

the technical reference standards.
Also ensure that the electrical installation cor-

responds to maximum absorbed power specifi-

cations as shown on the water heater data-plate. 

Water heaters are supplied complete with an 

“X” type power cable without plug. The power 

cable must be connected to a 230V ±10% / 50Hz 

mains, respecting L-N polarity and the earthing 

connection 

; this network must have a mul-

ti-pole circuit breaker with Class III overvoltage 

category. If the power supply cable is damaged, it 

must be replaced by a special cable or assembly, 

which are only available from the manufacturer 

or its After-sales Service. It is recommended to 

contact a qualified company (e.g. the Authorised 

After-Sales Technical Assistance Service) for 

replacement to avoid a hazard. The power cable 

must be laid as shown 

(Fig. 4)

.

Power cable

4

Содержание CAESAR ECO 17

Страница 1: ...Wall hung instantaneous water heaters with sealed chamber type C and fan assisted or open chamber type B and fan assisted IE Instructions and warnings Installer User Maintenance technician 1 043165EN...

Страница 2: ......

Страница 3: ...prevention it is necessary to comply with the provisions of the regulations in force and the principles of good practice Installation and maintenance must be performed in compliance with the regulati...

Страница 4: ...9Kits available on request 13 1 20Water heater components 14 2 Instructions for use and maintenance 15 2 1 Cleaning and maintenance 15 2 2 General warnings 15 2 3 Quick appliance operation guide 15 2...

Страница 5: ...sides of the cabinet Leave adequate space above and below the water heater for possible water and flue removal connections Ref Fig 2 Keep all flammable objects away from the ap pliance paper rags plas...

Страница 6: ...st be the same as or larger than the 3 4 G water heater fitting Before connecting the gas line carefully clean inside all the fuel feed system pipes to remove any residue that could impair water heate...

Страница 7: ...CONNECTION The Caesar Eco water heater has an IPX5D pro tection rating for the entire appliance Electrical safety of the appliance is reached only when it is correctly connected to an efficient earthi...

Страница 8: ...tension pipe needs shortening consider that the internal duct must always protrude by 5 mm with respect to the external duct N B for safety purposes do not obstruct the water heater intake exhaust ter...

Страница 9: ...2 8 Intake m 20 Exhaust m 15 Intake exhaust terminal horizontal concentric 60 100 m 1 9 Intake m 14 Exhaust m 10 6 Intake exhaust terminal vertical concentric 60 100 m 2 5 Intake m 18 Exhaust 14 Pipe...

Страница 10: ...oncentric vertical intake and exhaust kit This vertical terminal is connected directly to the out sideofthebuildingforairintakeandflueexhaust N B the vertical kit with aluminium tile enables installat...

Страница 11: ...external wall sealing plates are fitted Fit the exhaust pipe 9 with the male end smooth in the female end of the bend 5 up to the stop making sure that the internal wall sealing plate has been fitted...

Страница 12: ...y designed according to the calculation method and requirements of the standards such as EN 13384 by professionally qualified technical staff Chimney or flue sections forconnectionoftheflueexhaustpipe...

Страница 13: ...erature and anticlockwise to decrease it The symbol flashes for 5 seconds and the screen displays the new temperature set Appliance switch off Press and hold the water heater switch off button for app...

Страница 14: ...E TECHNICIAN 1 20 WATER HEATER COMPONENTS Key 1 Gas valve 2 Limit thermostat 3 NTC probe hot water outlet 4 Ignition detection electrode 5 Fan 6 Heat exchanger 7 Burner 8 NTC probe cold water intake 9...

Страница 15: ...se the mains water supply and ask an authorised com pany for assistance for example Authorised After sales Service Attention using any components that use electrical power requires some fundamental ru...

Страница 16: ...restarts automatically 1 Definite shutdown Limit thermostat alarm Press and hold the reset button As soon as the wording is displayed release the button The appliance restarts automatically 1 Tempora...

Страница 17: ...ures 1 Definite shutdown Software startup board error alarm 1 1 If the shutdown or fault persists contact an authorised company e g Technical After Sales Service 2 6 EMPTYING THE WATER HEATER To empty...

Страница 18: ...eat exchanger 3 Burner 4 Valve burner pipe 5 NTC probe cold water intake 6 Flow regulator 7 Flow meter 8 Gas valve 9 NTC probe hot water outlet 10 Nozzle manifold unit 11 Limit thermostat 12 Sealed ch...

Страница 19: ...IRING DIAGRAM Key EL Ignition electrode TR Ignition transformer F Fan FX DHW flow meter LT Limit thermostat SP DHW probe hot water output SI DHW probe cold water input GV Gas valve HM Gas shutter for...

Страница 20: ...of inactivity or in the event of overheating 67 C 3 3 SERVICE MENU Service Menu activation It is possible to access the SERVICE MENU in order to edit the operating parameters of the appliance With the...

Страница 21: ...must not be changed for any reason 3 4 POSSIBLE PROBLEMS AND THEIR CAUSES N B maintenance operations must be carried out by an authorised company e g Authorised After Sales Technical Assistance Servi...

Страница 22: ...t is therefore not necessary to replace them reassemble the components proceeding in reverse order if there are seals they must be restored Parameter change 02 type of gas Start the appliance and acce...

Страница 23: ...hes on the display then release the button the screen displays press the reset button again until the wording MENU flashes then release the button the screen displays the value of the set temperature...

Страница 24: ...ere are seals they must be restored 3 8 YEARLY APPLIANCE CHECK AND MAINTENANCE The following checks and maintenance should be performed at least once a year Clean the flue side of the heat exchanger C...

Страница 25: ...water heater maintenance the casing can be completely removed by following these simple instructions Fig 36 1 Loosen the lower screws a that secure the casing b 2 Pull the casing towards you b in the...

Страница 26: ...e refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15 C the values are measured directly at the water heater outlet considering that to obtain the data declared mixing with cold...

Страница 27: ...ter function AEC 28 kWh Annual fuel consumption for the domestic hot water function AFC 19 GJ Water heating energy efficiency wh 80 For proper installation of the appliance refer to Chapter 1 of this...

Страница 28: ...the actual energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the si...

Страница 29: ...30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the set of products indicated in this sheet may...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...mmergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Code 1 043165ENG rev ST 004073 001 12 19 Inglese...

Отзывы: