3.22 CASING REMOVAL
To facilitate boiler maintenance the casing can be completely re-
moved as follows:
Lower grid (Fig. 62)
- Loosen the two side screws (a).
- Loosen the two screws under the front panel (b).
- Remove the grid (c).
Casing and control panel (Fig. 63 - 64)
- Remove the covering caps (d).
- Then unscrew the two fixing screws on the control panel (e).
- Pull the casing (f) towards you and release it from its lower seat.
- Loosen the screw (g) that secures the control panel.