background image

IT

IE

Cod. 1.043889 - Rev. ST.004679/001 

IL PRESENTE FOGLIO È DA LASCIARE ALL'UTENTE 

ABBINATO AL LIBRETTO ISTRUZIONI DELLA CALDAIA

THIS SHEET MUST BE LEFT WITH THE USER ALONG WITH 

THE BOILER INSTRUCTION BOOKLET

KIT RICIRCOLO CALDAIE SERIE HERCULES 

KW, HERCULES CONDENSING KW

E HERCULES SOLAR

COD. 3.020001

KIT TUBO RICIRCOLO ABBINAMENTO 

ANODO ELETTRONICO CALDAIE 

SERIE HERCULES KW E HERCULES SOLAR

COD. 3.030689

HERCULES KW, HERCULES CONDENSING 

KW AND HERCULES SOLAR BOILER 

RECIRCULATION KIT

COD. 3.020001 

HERCULES KW AND HERCULES SOLAR 

BOILERS ELECTRONIC ANODE COUPLING 

RECIRCULATION PIPE KIT

COD. 3.030689

AVVERTENZE GENERALI.

Tutti i prodotti sono protetti con idoneo imballaggio da trasporto. 

Il materiale deve essere immagazzinato in ambienti asciutti ed al 

riparo dalle intemperie.

Il presente foglio istruzioni contiene informazioni tecniche relative 

all’installazione del kit. Per quanto concerne le altre tematiche corre-

late all’installazione del kit stesso (a titolo esemplificativo: sicurezza 

sui luoghi di lavoro, salvaguardia dell’ambiente, prevenzioni degli 

infortuni), è necessario rispettare i dettami della normativa vigente 

ed i principi della buona tecnica.

L’installazione o il montaggio improprio dell’apparecchio e/o dei 

componenti, accessori, kit e dispositivi potrebbe dare luogo a proble-

matiche non prevedibili a priori nei confronti di persone, animali, 

cose. Leggere attentamente le istruzioni a corredo del prodotto per 

una corretta installazione dello stesso.

L’installazione e la manutenzione devono essere effettuate in ottem-

peranza alle normative vigenti, secondo le istruzioni del costruttore e 

da parte di personale abilitato nonché professionalmente qualificato, 

intendendo per tale quello avente specifica competenza tecnica nel 

settore degli impianti, come previsto dalla Legge.

Nel caso di installazione del solo "Kit ricircolo" consultare le 

prossime 4 pagine del presente foglio istruzioni. 
Nel caso di montaggio del "Kit ricircolo" in concomitanza del "Kit 

tubo ricircolo abbinamento anodo elettronico" consultare per intero 

il presente foglio istruzioni. Ricordarsi inoltre di iniziare l'instal-

lazione dal "Kit tubo ricircolo abbinamento anodo elettronico".

GENERAL WARNINGS.

All products are protected with suitable transport packaging. 

The material must be stored in dry environments and protected 

against weathering.

This instruction manual provides technical information for installing 

the kit. As for the other issues related to kit installation (e.g. safety 

in the work site, environment protection, injury prevention), it is 

necessary to comply with the provisions specified in the regulations 

in force and principles of good practice.

Improper installation or assembly of the appliance and/or compo-

nents, accessories, kit and devices can cause unexpected problems 

to people, animals and objects. Read the instructions provided with 

the product carefully to ensure a proper installation.

Installation and maintenance must be performed in compliance with 

the regulations in force, according to the manufacturer's instructions 

and by authorised professionally qualified staff, intending staff with 

specific technical skills in the plant sector, as envisioned by the Law.

If only the “Recirculation kit” is installed, consult the next 4 

pages of this instruction manual. 
If the “Recirculation kit” is installed together with the “Electronic 

anode coupling recirculation pipe kit”, consult this instruction 

manual in full. Remember also to start the installation from the 

“Electronic anode coupling recirculation pipe kit”.

Содержание 3.020001

Страница 1: ...ionalmente qualificato intendendo per tale quello avente specifica competenza tecnica nel settore degli impianti come previsto dalla Legge Nel caso di installazione del solo Kit ricircolo consultare l...

Страница 2: ...STALLAZIONE KIT RICIRCOLO Hercules kW e Hercules condensing kW Fig 1 Si suggerisce di lubrificare tutte le connessioni O Ring tramite comune sapone liquido diluito leggermente con acqua Togliere tensi...

Страница 3: ...per l acqua potabile ATTENTION this circulator is indicated for drinking water only Nelcasodimontaggiodell anodoelettronico utilizzare il kit 3 030689 e fare riferimento alla fig 3 If the electronic a...

Страница 4: ...a caldaia Smontare la mantellatura della caldaia Preparazione impianto Accertarsi che il rubinetto ingresso acqua fredda 12 sia chiuso e abbassare la pressione all interno del bollitore aprendo momen...

Страница 5: ...to circolatore indicato solo per l acqua potabile ATTENTION this circulator is indicated for drinking water only If the electronic anode is installed use the 3 030689 kit and refer to fig 3 Nel caso d...

Страница 6: ...to 3 di Fig 1 non verr utilizzato Per i collegamenti degli anodi fare riferimento al foglio istruzioni dei kit cod 3 030694 e cod 3 029643 ELECTRONIC ANODE COUPLING RECIRCULATION PIPE KIT INSTALLATION...

Страница 7: ...mm Flat gasket seal 16 Plug G 1 2 F Present on storage tank cylinder Present in the recirculation kit 3 020001 Composizione kit 1 Nipples 3 4 3 4 maschio 2 O Ring EPDM 3 Gruppo raccordo inferiore con...

Страница 8: ...nto 3 di Fig 2 non verr utilizzato Per i collegamenti degli anodi fare riferimento al foglio istruzioni dei kit cod 3 030694 e cod 3 029643 Hercules solar Fig 4 It is recommended to lubricate the O Ri...

Страница 9: ...6 Locking fork 7 Electronic anode 8 Quick coupling fitting M 1 2 RC L 32 Present on storage tank cylinder Composizione kit 1 Nipples 3 4 3 4 maschio 2 O Ring EPDM 3 Gruppo raccordo inferiore con tubo...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: