background image

 

PAGE 9 

 

SENSO

RS AN

D INS

TRUME

N

TATIO

N F

OR MAC

HINE 

CON

DITION M

ONIT

ORIN

G

 

Warning:

 Do not make any adjustments to the internal potentiometers. These potentiometers are used for 

factory calibration and adjusting them will require return of the 682B05 to the factory for recalibration. 

 
Internal Switch Settings 

 

The internal switches of the Model 682B05 must be configured for the Full Scale Output of the ICP

®

 Sensor 

connected to it. This is accomplished by removing the front cover and sliding the PC Board out of the Signal 
Conditioner. Once removed, the switches should be configured per one of the conditions in the following table.  
 

Bearing Fault Detector:

 Set 

S1

 

for 1kHz or 5kHz (based on running speed). Range is fixed at 50g’s Peak. 

 

Overall Vibration:

 

Range Setting 

S2 

S3 

S4 

S5 

S6 

5g RMS 

UP 

UP 

ON 

OFF

 

OFF 

5g Peak 

UP 

DOWN

 

ON 

OFF

 

OFF 

10g RMS 

UP 

UP 

OFF 

ON

 

OFF 

10g Peak 

UP 

DOWN

 

OFF 

ON

 

OFF 

20g RMS 

UP 

UP 

OFF 

OFF

 

ON 

20g Peak 

UP 

DOWN

 

OFF 

OFF

 

ON 

0.5 in/sec RMS 

DOWN 

UP 

ON 

OFF

 

OFF 

0.5 in/sec Peak 

DOWN

 

DOWN

 

ON 

OFF

 

OFF 

1.0 in/sec RMS 

DOWN

 

UP 

OFF 

ON

 

OFF 

1.0 in/sec Peak 

DOWN

 

DOWN

 

OFF 

ON

 

OFF 

2.0 in/sec RMS 

DOWN 

UP 

OFF 

OFF

 

ON 

2.0 in/sec Peak 

DOWN

 

DOWN

 

OFF 

OFF

 

ON 

Note: Factory Default Setting is 1.0in/sec Peak 

Recommended Alert and Alarm Settings for Fault Detector: 
 

Although each machine will have alert and alarm settings at various levels based on its high frequency spectra, 
data has been provided as a baseline to approximate what these limits should be. Note that this data is a 
recommendation and levels should be adjusted according to measurements taken from a detailed vibration 
analysis and/or machine history. Please contact IMI Sensors for additional information and support regarding Alert 
and Alarm settings. 

 

Recommended Fault Detector Alert and Alarm Limits 

 

Speed Range (RPM) 

Alert Limit (Peak g-level) 

Alarm Limit (Peak g-level) 

Less than 5 

0.100 

0.180 

5 - 10 

0.150 

0.270 

10 - 20 

0.200 

0.360 

20 - 60 

0.400 

0.720 

60 - 150 

1.000 

1.800 

150 - 400 

2.000 

3.600 

400 - 700 

4.000 

7.200 

700 - 4000 

5.000 

9.000 

4000 - 10000 

7.000 

12.600 

 
 

 
 
 

Содержание 682B05

Страница 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 5: ...ING Model 682B05 Bearing Fault Detector Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IM...

Страница 6: ...CONDITION MONITORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 4 Configuring the 682B05 Page 8 ESD Sensitivity Page 10 Warranty Servicing Warranty Service Ret...

Страница 7: ...al Features Early detection of high frequency impact faults related to bearing failure and lube starvation External transmitters signal conditioners and ICP power supplies can be eliminated by direct...

Страница 8: ...l 682B05 is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682B05 in a type NEM...

Страница 9: ...osure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devices...

Страница 10: ...12 and BNC Jack Pin 9 RV Pin 10 RV Pin 11 No Connection Pin 12 No Connection 4 to 20mA Fault Detector Output Pins 13 14 Pin 13 4 to 20mA Fault Output Pin 14 4 to 20mA Fault Output 4 to 20mA Overall Vi...

Страница 11: ...UMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram Note If using the 682A01 mount the 682B05 to the left side of the power supply as shown with a recommended minimum separation distanc...

Страница 12: ...s The switches are used to configure the 682B05 for various sensor and vibration ranges The PC Board is accessible through the front of the conditioner by removing the Screw Terminal Connectors and di...

Страница 13: ...N 20g Peak UP DOWN OFF OFF ON 0 5 in sec RMS DOWN UP ON OFF OFF 0 5 in sec Peak DOWN DOWN ON OFF OFF 1 0 in sec RMS DOWN UP OFF ON OFF 1 0 in sec Peak DOWN DOWN OFF ON OFF 2 0 in sec RMS DOWN UP OFF O...

Страница 14: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Страница 15: ...oid any warranty If factory service is required return the instrumentation according to the Return Procedure stated below A repair and or replacement quotation will be provided prior to servicing at n...

Страница 16: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Страница 17: ......

Отзывы: