PAGE 17
SENSO
RS AN
D INS
TRUME
N
TATIO
N F
OR MAC
HINE
CON
D
ITION M
ONIT
ORIN
G
Programming Sections
The screen has three sections:
649A03 Sensor Data
– This section displays the current vibration data in g’s peak, g’s RMS and HF g’s
RMS
(g’s RMS with 2.5 kHz high-pass filter applied)
Actual 649A03 Settings
– This section shows the settings currently programmed in the sensor.
649A03 Settings to Write
– This section shows the options for programming the sensor.
Figure 21
– Typical Screen After Successful Parameter Read
Reading and Writing Parameters
Reading Parameters - To read the current sensor settings, click the Read Parameters button. This
operation takes approximately 45 seconds to complete.
Transferring Actual Settings to Settings to Write Field -
Use the ‘>>>’ button to transfer all Actual Settings
to the Settings to Write fields.
Writing Parameters- Select the appropriate mode and enter any pertinent parameter information. Click the
Set Parameters button. This causes the settings to be sent to the sensor and then read back and
displayed in the Actual 649A03 mode.
Figure 22
– Transferring Actual Settings to Settings to Write Field