10. Valve island extension
Valve islands can be extended using the 2- and 4-station PCBs as described in this chapter.
The following PCBs are available for the extension:
VS2672762-KG00
VS2672761-KG00
VS2672764-KG00
4 station PCB
2 station PCB
(new) 2 station PCB
shall only be mounted at the end in
below configurations
10.1 Overview
– possible combinations
Below illustration shows an overview of the preferred combinations of existing PCBs in order to
build the required number of valve stations.
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
4
4
6
4
2
8
4
4
10
4
4
2
12
4
4
4
14
4
4
4
2
14
4
4
4
4
18
4
4
4
4
2
20
4
4
4
4
4
4
2
4 station PCB
2 station PCB
Note:
It is generally possible to use the new 2 station PCBs (VS2672764-KG00) on all positions but it is
recommended to use the above combinations.
In special cases with increased modularity requirements, the product support should be contacted.
The below sections show the preferred combinations of the existing SPI boards for various valve
island configurations.