J.
Cable should follow the contour of the gripper jaw
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2017 Norgren Automation Solutions, LLC
09
2/17
12680UI REV: 003
I. Installing an In-Pad Sensor
1)
If an
In-Pad Sensor
is to be installed, it goes on top of the side plate assembly. Wrap sensor cable through holder
and align holes on side plate. Clean and apply liquid Loctite 262 or equivalent to 2X M5 X 10 mm SHCS and thread
thru sensor into side plate. Tighten both SHCS to
36in-lb
.
2)
Apply liquid Loctite 262 or equivalent to sensor bolt, place thru jaw and tighten
120in-lb
.
User Instructions for PGS20 and PGS42 Grippers
Cable storage loop can be adjusted with a push/pull motion
to provide more or less cable slack in gripper jaw area.