background image

USER MANUAL

 

 

7

cleaning it. Only handle the power-cord by the plug. Never pull out the plug by 

tugging the power-cord. 

z

 

It is essential to connect the yellow/green conductor to earth. 

z

 

The electric connection, repairs and servicing must be carried out by a 

qualified employee. 

z

 

Do not switch the fixture on and off in short intervals as this would reduce the 

laser diode life. 

z

 

For replacement, please use fuses of same type and rating only. 

z

 

If the device has been exposed to drastic temperature fluctuation, do not 

switch it on immediately. The arising condensation water might damage your 

device. Leave the device switched off until it has reached room temperature.. 

z

 

Do not shake the device. Avoid brute force when installing or operating the 

device. 

z

 

When choosing the installation-spot, please make sure that the device is not 

exposed to extreme heat, moisture or dust. There should not be any cables 

lying around. You endanger your own and the safety of others! 

z

 

The minimum distance between the fixture and surrounding walls must be 

more than 50cm. 

z

 

Always fix the fixture with an appropriate safety-rope. Fix the safety-rope at 

the safety-rope only. 

z

 

The ambient temperature must be between 10

 to 40

z

 

Please use the original packaging if the device is to be transported. 

z

 

Please consider that unauthorized modifications on the device are forbidden 

due to safety reasons! 

 

 
 
 
 
 
 
 
 
 
 
 

 

CAUTION!  Operate the device only after having familiarized with 

its functions.

 

Do not permit operation by persons not 

qualified for operating the device. Most damages are 
the result of unprofessional operation   

CAUTION!    If this device will be operated in any way different to the 

one described in this manual, the product may suffer 
damages and the warranty word.

Содержание LSX-300SRGB

Страница 1: ...ant laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this manual in a safe place for future reference ...

Страница 2: ...aser incident or damage Prevent damage or injury from incorrect operation Laser safety warming labels To protect the environment recycle packing material wherever possible The projector is for indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects Don t thro...

Страница 3: ...le parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure NON INTERLOCKED HOUSING WARNING This unit contains high power laser devices inter...

Страница 4: ...ms or laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliwatts of laser power Class 3B levels internally Many of the individual beams are potentially hazardous to the eyes It is also incorrect to assume that because the laser light is moving it is safe This is not true Nor do the laser beams always move Since eye in...

Страница 5: ...in any way z Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury z Never leave this device running unattended z The operation of a Class 3B laser show laser is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in this manual z The legal requi...

Страница 6: ...N DATA As measured under IEC measurement conditions for classification Note The laser diode is exposed to extreme conditions due to the high output power and therefore only has a limited life Like all wear parts the laser diode is not subject to any guarantee claims Laser Classification Class 3B Beam Diameter 5mm at aperture Divergence each beam 2 mrad Divergence total light 40 degrees Cooling TEC...

Страница 7: ...device z Please consider that damages caused by manual modifications to the devise are not subject to warranty z Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution z Make sure that the available voltage is not higher than stated on the rear panel z Always plug in the power plug least Make sure that the power...

Страница 8: ...the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others z The minimum distance between the fixture and surrounding walls must be more than 50cm z Always fix the fixture with an appropriate safety rope Fix the safety rope at the safety rope only z The ambient tem...

Страница 9: ...ox and packing What is included The carton or flight case contain following items Power Supply To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture of refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched cir...

Страница 10: ... in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection Caution At the laser fixture the DMX cable has to terminate with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug and plug it in the DMX output ...

Страница 11: ...plug it in the DMX output of the last fixture z Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system z The DXM outp...

Страница 12: ...r light and audience or other public spaces Rigging the Fixture z The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation z The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part ...

Страница 13: ...ear z The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated PRODUCT OVERVIEW z This device has left out premise in absolutely perfect condition In order to maintain this condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual z The manufacturer will...

Страница 14: ...cated LED Red is ON 3 MUSIC IR Synchronize to detected music signal IR indicator flashing for each signal received 4 IR Infrared Remote Receiver 5 HANGING BRACKET with 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook 5 Cooling fan Cooling and never cover this fan outlet ...

Страница 15: ...b or start servicing z In the event of serious operation problems stop using the fixture and contact your dealer immediately NO NAME FUNCTION 7 Switch Switch on and off the power 8 Mains input With socket and integrated fuse holder 9 Key switch Make sure the professional person use 10 Interlock For emergency laser stop 11 LED control Panel Intelligent LED control panel of the system 12 Safety eye ...

Страница 16: ...ry resetting and saved the new mode information will be shown on LCD monitor at next power on Mode Option to choose the operating mode of laser Confirmation to confirm the laser to show the present mode at the next operation UP DOWN to change operating mode parameter or DMX address OPERATION SCAN S 50G RE SCAN S 100G RE SCAN S 400B RE DISPALY STAND ALONE MODE PREPROGRAM EFFECT AUF Auto show with f...

Страница 17: ...ont panel of laser will be ON SLAVE MODE z Press FUNC to enter MODE selection z Till to LED panel shows SLA z Press ENTER to confirm setting The laser is working in SLAVE MODE Connect MASTER laser with several SLAVE laser with DMX cable SLAVE lasers are doing exactly the same laser show as MASTER laser Please check chapter for DMX cable connection for reference REM MODE Remote Optional z Press FUN...

Страница 18: ... panel and the laser will show pattern right side z Press ENTER to confirm the setting z With help of UP button the laser scanned world in x direction could be reversed as the graphic as below z With help of DOWN button the laser scanned world in y direction could be reversed as the graphic as below Remote Instruction Optional ...

Страница 19: ...ivity setting 9 is the most sensitive COLOR CHANGING Cycle through Programmed Color Color 3 Color 2 Color 1 PATTERN CHANGING To show and change patterns FIXED PATTERN Choose favorite PATTERN from 1 to 48 PATTERN REPEAT Last PATTERN and current PATTERN cycle repeating Attention Any control or setting in remote will be saved in ram until the system is rebooted The system is in AUTO show in any first...

Страница 20: ... 000 255 Every 16 for 1 group total 80 patterns CH 4 COLOR 000 007 Original 008 015 Red 016 023 Green 024 031 Yellow 032 039 Blue 040 047 Purple 048 055 Light Blue 056 063 White 064 111 Color Rolling 112 159 Color Jumping 160 207 Color Moving 208 255 Strobing CH 5 CLIPING 000 Full pattern without clipping 001 127 0 99 fixed pattern clipped 128 255 Clipping Speed ...

Страница 21: ...xed X axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling CH 11 ROLL 0 255 Fast to Slow CH 12 Z AXIS ROLLING 000 127 0 359 degree fixed Z axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling CH 13 ROLL 0 255 Fast to Slow CH 14 X AXIS MOVING 000 127 128 different fixed position on X axis 128 191 Clockwise moving 192 255 Anticlockwise moving CH 15 MOVE 0 255 Fast to Sl...

Страница 22: ...USER MANUAL 21 PATTERN LIST ...

Страница 23: ...annels Measurement N Weight AC100 240V 50 60Hz 250V 1A Slow Blow 20mm Glass 15W 20 Audio Sound Activated 150mW 650nm red 50mW 532nm green 80mW 450nm blue Class 3B EN60825 1 2007 10 40 3 pins XLR Male Female Max 17 channels See picture below 1 5Kg Every information is subject to change without prior notice The availability of particular products may vary by region Please check with the dealer ...

Отзывы: