Electric connection
The device is planned for the connection at 240/400 (see rating plate). Mounting a norm
coupler according to the rating plate.
At a substitution of the
connecting cable
the back wall (Dissolution of 4 screws) is to be
removed; the terminal is then
accessible
. If a direct connection is requested onto the mains, a
single-pole counter with a minimum contact gap of 3 mm, according to the valid
norms
, is
necessary. The yellow-green earthing must not be disturbed. Always a
connecting cable
is to
be employed, which one is constant for temperatures about 50 ° C or so one of the model
H05
RR
F
.
Before the bonding make sure that:
1. the incoming line sufficiently is protected,
2. the socket according to the rules is grounded,
3. the coupler or combined the single-pole counter is correctly with the device.
The insulation material in the stove and fat residues from the production develop smoke and
unpleasant odours. Therefore we recommend during the first
use
to warm up the stove with
opened door for approximately 30 minutes on the maximum temperature stage.
We refuse every liability if the safety norms are not kept.
Connection diagram
L1
N
E
240 volt
L1
L2
L3
N
E
400 volt
Placement
To a slightly inflammable wall the device must have a distance of 2 cm. If placement of this
device in close distance of walls, partitions, kitchen furniture, decorative linings and so forth,
it is recommended that these are produced from not inflammable material, otherwise
they
must be dressed up with characterized not inflammable material. The most precise
observation of the rules of the fire protection must be guaranteed.