5 Passwords

The device can be protected by passwords, to avoid unauthorized persons to read data or modify
parameters.

As default passwords are equal to 0.

Allowed values range from 0 to 999999999 (only numbers).

To change the passwords, set the new values with the LoRa Tool App:

www.ime.de

Содержание enginko EGK-LW20W00

Страница 1: ... 1 Technical data 2 2 2 Installation 2 2 3 Power ON OFF 9 2 4 System leds 11 2 5 Battery 11 2 6 Firmware update 15 3 Measures 16 3 1 Level settings 17 4 LoRaWAN network 22 4 1 Activation 23 4 2 Other settings 24 5 Passwords 26 6 Configuration file 28 6 1 Multi devices configuration 29 7 LoRaWEB Tool 30 8 Payload 31 9 Ordering code 31 10 Declaration of conformity 31 11 Contacts 31 www ime de ...

Страница 2: ...Last update 2022 05 17 15 44 manual_egk lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 www ime de ...

Страница 3: ... users Pursuant to and in accordance with Article 14 of the Directive 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE and pursuant to and in accordance with Article 20 of the Directive 2013 56 EU of the European Parliament on batteries and accumulators and waste batteries The barred symbol of the rubbish bin shown on the equipment indicates that at the end o...

Страница 4: ...ubstances replacement possible Pole or surface mount 5 years life time with SF12 and max Tx power 48 Uplinks messages per day Transmission 868 MHZ 14dBm max BLE 5 0 interface for configuration data reading and FW upgrade Remote configuration 3 Storage temperature 30 C 80 C Working temperature 30 C 70 C Dimensions 64 5 58 5x39mm Protection grade IP67 Weight 90g 2 2 Installation To ensure correct oper...

Страница 5: ...com support Alternatively the sensor can be mounted to overfill detection on the side of the lid In this case level parameters need to be modified Custom brackets available on request 2 2 1 Bin lid or side mount For mounting onto the lid or side of the bin use the provided screws and spacers www ime de ...

Страница 6: ...ast update 2022 05 17 15 44 manual_egk lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 2 2 1 1 Lid mount examples www ime de ...

Страница 7: ...2 07 07 14 23 5 31 manual_egk lw20w00 e n g i n k o s u p p o r t c e n t e r https www enginko com support 2 2 2 Wall mount For mounting onto wall use the optional wall mount bracket EGK RAWALL www ime de ...

Страница 8: ...Last update 2022 05 17 15 44 manual_egk lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 www ime de ...

Страница 9: ... t e r https www enginko com support 2 2 3 Pole mount For installation on poles pillars or posts use the included bracket and fasteners 2 2 4 LoRa Tool To deploy the sensor download the latest LoRa Tool Android App to setup LoRaWAN credentials and other preferences www ime de ...

Страница 10: ...rt doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 2 2 5 Connection Enable the Bluetooth on the smartphobne and open the App once the sensors list appears as BLE MAC address select the sensor you need to configure and read it www ime de ...

Страница 11: ...m support 2 3 Power ON OFF The sensor is shipped completely off to prevent battery consumption during storage It is therefore necessary to carry out a first power on prior to commissioning To power on the sensor lay the magnet at the bottom of the provided tool into the area shown in the figure www ime de ...

Страница 12: ..._egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 Successful power on is signaled by the flashing of the 3 LEDs In case of long period of inactivity if necessary is possible to shut off again the sensor to prevent battery consumption via downlink or with LoRa Tool App www ime de ...

Страница 13: ...2 5 Battery This sensor contains lithium battery which must be disposed of separately EGK LW20W00 is provided with a battery pack Code Description EGK 1S2PCR 4800mAh battery pack This is the estimated battery life in years in the worst conditions 10min reading 15min reading 30min reading SF12 2 3 5 SF7 4 5 8 2 5 1 Battery replacement remove the front panel of the sensor with a small screwdriver ww...

Страница 14: ...l_egk lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 remve the PCB batteries pack from the main board PCB board is secured with two small screws www ime de ...

Страница 15: ...2022 07 07 14 23 13 31 manual_egk lw20w00 e n g i n k o s u p p o r t c e n t e r https www enginko com support Place the new PCB batteries pack and put them in place with the screws www ime de ...

Страница 16: ...o com support Printed on 2022 07 07 14 23 Place the front panel and fix it with the 4 screws After the batteries replacement internal counters need to be resetted To perform the operation you need a unique reset code that must be requested to enginko please provide the DevEUI of the sensor when you ask for that code www ime de ...

Страница 17: ...l_egk lw20w00 e n g i n k o s u p p o r t c e n t e r https www enginko com support At the end of the procedure the battery level displays 100 2 6 Firmware update Download the latest firmwares available on the smartphone www ime de ...

Страница 18: ...s www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 Upload it with LoraTool App 3 Measures On each reading of the sensor by LoraTool the measured distance is shown on the main page www ime de ...

Страница 19: ...g level timestamp to the server via uplink 3 1 Level settings Level measurements are carried out according to few parameter settings A target over the defined range cannot be detected Read and write of parameters can be done using LoRaTool App They have a default value and can be modified to be tailored on the specific use case Meaning of parameters is related to following diagram The REFERENCE dista...

Страница 20: ...0w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 3 1 1 Start mm Starting point of the measurement in mm from REFERENCE point Values can be set from 140 to 1360 www ime de ...

Страница 21: ...com support Default 140 A target within the Start mm distance will result at a Start distance The Start mm value is also related to other level parameters Contact enginko in case of assistance 3 1 2 Lenght mm Range of measure in mm from Start point Values can be set from 0 to 1500 Start mm www ime de ...

Страница 22: ...lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 Default 1360 3 1 3 Signal threshold Minimum target detection threshold Values can be set from 1 to 20000 www ime de ...

Страница 23: ...07 07 14 23 21 31 manual_egk lw20w00 e n g i n k o s u p p o r t c e n t e r https www enginko com support Default 200 3 1 4 Power Power setting for target detection Values can be set from 1 to 5 www ime de ...

Страница 24: ...anual_egk lw20w00 https www enginko com support doku php id manual_egk lw20w00 https www enginko com support Printed on 2022 07 07 14 23 Default 3 4 LoRaWAN network The sensor is compliant with LoRaWAN specification 1 0 2 www ime de ...

Страница 25: ...a LoRaWAN network NONE sensor not activated 1 OTAA the JoinEUI and the AppKey not setted must be written to the device 2 OTAA MCF88 Over the air activation fixed keys JoinEUI 904e915000000001 AppKey on 3 request OTAA ENGINKO Over the air activation fixed keys JoinEUI 904e915000000001 AppKey on 4 request ABP requires writing to the device of NwkSkey AppSkey DevAddr 5 www ime de ...

Страница 26: ... sync at every power on uplink starting with 01 or once a week If no or wrong reply received it will retry after 1 hour If not handled in the right way can cause a unnecessary battery consumption battery life 2 years Please check chapter 2 1 DATA FRAME FORMAT 4 2 Other settings Network settings please keep Any settings Change it only if Objenious network is used default_ any Network type LoRa sync...

Страница 27: ...efault enabled UnConfirmed set for unconfirmed uplinks default confirmed uplink Led OFF set to disable the led Single join day set for to allow only one join per day default multiple join allowed Period time interval between two measures in minutes Clock timed set to sincronize the reading with the internal clock Accelerometer set to enable asynchronous measure in case of shaking useful for debug www...

Страница 28: ...ko com support Printed on 2022 07 07 14 23 5 Passwords The device can be protected by passwords to avoid unauthorized persons to read data or modify parameters As default passwords are equal to 0 Allowed values range from 0 to 999999999 only numbers To change the passwords set the new values with the LoRa Tool App www ime de ...

Страница 29: ...k lw20w00 e n g i n k o s u p p o r t c e n t e r https www enginko com support Once the passwords are setted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the device www ime de ...

Страница 30: ...vEUI of the sensor when you ask for that code 6 Configuration file WIth LoRa Tool App is possible to configure the device using an XML file instead to manually adjust the parameters for details about the file format please ask to enginko This is very useful especially in case of multiple devices configuration With Save button an XML file with the actual configuration of the sensor will be generated This i...

Страница 31: ...parameters Activation Type AppKey AppEUI NetKey DevAddress Band Private option for each sensor based on DevEUI When the sensor is approached if one parameter is different from files the APP will ask you if you want to overwrite XLS is prevailing on the XML so if both files are enabled if the DevEUI of the device matches one of the DevEUIs in the XLS file LoRa parameters will be setted from this one Th...

Страница 32: ...upport Printed on 2022 07 07 14 23 For details on files format please ask to enginko 7 LoRaWEB Tool enginko provides upon free registration LoRaWEB online tool where for each sensor it is possible to find documentation javascript examples for parsing downlink generator and uplink decoder LoRaWEB Tool iot mcf88 cloud LoRaWeb www ime de ...

Страница 33: ...ount bracket 10 Declaration of conformity Hereby enginko Srl declares that EGK LW20W00 complies with the essential requirements and other relevant provisions of Directive 2014 53 EU 11 Contacts enginko Srl Via Roma 3 I 28060 Sozzago NO T 39 0321 15 93 088 E info enginko com PEC enginkosrl legalmail it W enginko com Document rev 3 1 2 3 Future development From https www enginko com support e n g i ...

Отзывы: