WATER SUPPLY
Connect the water supply pipe to the hose tail located on the top of the cylinder.
Fit the other end of the supply pipe to a cold water supply.
PLEASE NOTE:
these machines are fitted with an air-break to prevent back
syphonage into the mains supply, but some local authorities may nevertheless
require connection to a storage cistern rather than direct to the mains supply.
This applies to UK installations only. Overseas customers should install the
machine in accordance with local regulations.
IF IN DOUBT, CHECK WITH YOUR LOCAL AUTHORITY
WASTE OUTLET CONNECTION
If empting the waste into a sink is not desired then the peeler can be plumbed into
the waste pipes. The waste outlet pipe fits over standard 2” pipe and should be
secured by a jubilee clip. The length of the pipe should be kept to a minimum and
the size must not be reduced. The pipe must have a fall of at least 1:15 and
changes of direction should be made by swept bends rather than elbows.
Cleaning eyes should be fitted where possible in accordance with standard
plumbing practice.
Waste ejector (Optional Extra)
The waste ejector is a fitting that dilutes the waste sludge to enable it to flow easily
through the drains.
Waste Ejectors are not recommended in the follow circumstances;
A pipe run exceeding 15m between the machine and main drain
When a fall of 1:15 cannot be achieved
When piping is exceptionally complex
In any of the above cases an interceptor tank is recommended.