background image

Publication No ST1001F  February 2001

Imperial Machine Company Limited
Harvey Road, Croxley Green, Herts WD3 3AX, England
Telephone: 01923 718000: Interna 44 1923 718000
Fax: 01923 777273: Interna 44 1923 777273
Telephone: Service 01923 718017  Spares 01923 718018  Fax: 01923 896256

INSTRUCTIONS FOR

INSTRUCTIONS FOR

INSTRUCTIONS FOR

INSTRUCTIONS FOR

INSTRUCTIONS FOR
INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION OPERA

TION OPERA

TION OPERA

TION OPERA

TION OPERATION AND MAINTENANCE

TION AND MAINTENANCE

TION AND MAINTENANCE

TION AND MAINTENANCE

TION AND MAINTENANCE

VC7 Ser

VC7 Ser

VC7 Ser

VC7 Ser

VC7 Series 22, 

ies 22, 

ies 22, 

ies 22, 

ies 22, VC14 Ser

VC14 Ser

VC14 Ser

VC14 Ser

VC14 Series 25

ies 25

ies 25

ies 25

ies 25

V RANGE PO

V RANGE PO

V RANGE PO

V RANGE PO

V RANGE POT

T

T

T

TA

A

A

A

AT

T

T

T

TO PEELING MA

O PEELING MA

O PEELING MA

O PEELING MA

O PEELING MACHINES

CHINES

CHINES

CHINES

CHINES

Cl/SfB

(73.4)

X

Содержание VC14 Series 22

Страница 1: ...ONS FOR INST INST INST INST INSTALLA ALLA ALLA ALLA ALLATION OPERA TION OPERA TION OPERA TION OPERA TION OPERATION AND MAINTENANCE TION AND MAINTENANCE TION AND MAINTENANCE TION AND MAINTENANCE TION A...

Страница 2: ...x Page Page Page Page Page Index 1 On Delivery 2 Guarantee 2 Installation 2 Electricity Supply Connection 3 Water Supply 4 Waste Discharge 5 Operation and Maintenance 6 Maintenance and Spare Parts 7 W...

Страница 3: ...on to the wrong electricity supply or fair wear and tear are not covered by the guarantee Please observe these instructions carefully Please observe these instructions carefully Please observe these i...

Страница 4: ...TION INSTRUCTIONS SUPPLY CONNECTION INSTRUCTIONS ELECTRICITY SUPPLY CONNECTION ELECTRICITY SUPPLY CONNECTION ELECTRICITY SUPPLY CONNECTION ELECTRICITY SUPPLY CONNECTION ELECTRICITY SUPPLY CONNECTION E...

Страница 5: ...h off and interchange any two of the phase lead connections WATER SUPPLY CONNECTION WATER SUPPLY CONNECTION WATER SUPPLY CONNECTION WATER SUPPLY CONNECTION WATER SUPPLY CONNECTION Connections should o...

Страница 6: ...the machine and main drain 2 When a fall of 1 15 cannot be achieved 3 When the piping is exceptionally complex In any of these cases use instead an interceptor tank Water for the ejector must be take...

Страница 7: ...es into a container which holds a known measured weight and take out any stones which could jam the machine or damage the abrasive Should this happen the noise will indicate the presence of a stone sw...

Страница 8: ...ards in its slots W W W W WARNING ARNING ARNING ARNING ARNING D D D D DISCHARGE ISCHARGE ISCHARGE ISCHARGE ISCHARGE THE THE THE THE THE CAPACITORS CAPACITORS CAPACITORS CAPACITORS CAPACITORS BEFORE BE...

Страница 9: ...Diagram VC7T VC14T 1 phase Timer Wiring Diagram VC7T VC14T 1 phase Timer Chassis Earth Gn Y Bl Bn Line Earth Neutral 1 5 2 4 Timer Bk Bk E U2 Motor U1 Wiring DiagramVC7 VC14T 3 phase Wiring DiagramVC...

Страница 10: ...o SK1125B Drawing No SK1125B Drawing No SK1125B Drawing No SK1125B Setting Setting Setting Setting Setting Dimension Dimension Dimension Dimension Dimension V V V V VC7 3 C7 3 C7 3 C7 3 C7 3 0 0 0 0 0...

Страница 11: ...0 29 G40 120 G40 120 Motor 1 ph 240 1 50 30 A06 010 A06 010 Pulley 1 A Section S58 110 S58 110 MotorAssembly380 420 3 50 G40 121 G40 121 Motor 3 ph 380 420 3 50 A06 010 A06 010 Pulley 1 A Section 31 A...

Отзывы: