MR60 – GLASS FROSTER
10
ELECTRICITY SUPPLY CONNECTION
Position the unit in the chosen site. The electricity supply connection should be
made to a power outlet socket or isolator mounted on the wall close to the
machine. This socket or isolator must be accessible once the machine is
installed. Before connecting, check that the voltage shown on the rating label is
correct for the electricity supply you have available. If the plug does not fit your
sockets or a longer lead is required, changes must be made by an approved
electrician.
NOTE: The plug is fitted with a 10amp fuse.
The plug fuse cover must be refitted when changing the fuse. In the event of
losing the fuse cover the plug must NOT be used until a replacement fuse cover
has been obtained and fitted or the plug replaced.
WARNING: This machine must be earthed
Should the supply cord become damaged then a replacement must be fitted by
an approved electrician. The IEE Codes of Practice must be observed.
The wires in the mains lead are coloured in accordance with the following code
Green and yellow
Earth
Blue
Neutral
Brown
Live
COMMISSIONING
Before using a bottle cooler for the first time, the interior should be wiped out
with a clean damp cloth.
Allow the machine to stand for 1 hour to allow the refrigerant to settle. Plug in
and switch on at the wall socket. There is no separate switch to turn on the
machine. The compressor will start running less than one minute after the
supply is switched on.
Check that the light is working.
Run the unit empty, and check that cold air is being circulated within the
cabinet.