Procedure 
 

WARNING  

The following table shows the weight and the minimum quantity of 
people required to lift each unit: 

 

Bottle Cooler 

Net Weight 

Quantity of 

People 

M60 

52 kg 

M90 

82 kg 

M135 

125 kg 

TC60 

87 kg 

 
Install the unit on a flat and level floor.  The Mistral M60 and M90 require 20mm 
clearance for air circulation at the back and sides. The units are fitted with glider 
feet which allow them to slide forward for cleaning and maintenance purposes.  
The Mistral TC60 requires a clearance of 40 mm at the back of the unit.  
The Mistral M135 is on castors to aid installation and removal for cleaning. Do 
not install the unit close to a heat source such as a radiator or the warm air 
outlet of another piece of refrigeration equipment.  
Ensure that the units are standing level by adjusting the feet on either end of the 
front of the unit. 
 
The units have an automatic defrost cycle and evaporate all the condensate 
water without the need for a drainage system. 
 

NOTE 
The castors on the Mistral M135 are to aid installation only.  The unit is 
not designed as a mobile machine. 
 
It is important to install the Bottle Cooler on a flat surface. This ensures 
that the doors are level. Adjustment is provided via the feet, to enable the 
installer to level the cabinet. Engineer Call-outs in order to level Bottle 
Coolers, will not be covered under warranty.  

Содержание MISTRAL M135

Страница 1: ...LIDING DOOR SERIES 11 M60HA M90HA SERIES 1 MISTRAL TC60 SERIES 11 Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 72999...

Страница 2: ...mentation are in conformity with the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC and manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immun...

Страница 3: ...TC60 13 CHANGING A FLUORESCENT STRIP LIGHT FITTING M60 M90 M90SD M135 14 MAINTENANCE 15 DO S AND DON TS 16 ORDERING SPARE PARTS 17 END OF LIFE DISPOSAL 17 MATERIAL CONTENT 17 M60 WIRING DIAGRAM 18 M9...

Страница 4: ......

Страница 5: ...ng electricity supply or fair wear and tear are not covered by the guarantee The guarantee applies in this form to installations within the United Kingdom Please observe these instructions carefully D...

Страница 6: ...ND TC60 Check that the correct machine has been supplied and that the voltage marked on the rating plate is suitable for the supply available The rating plate is located on the right hand side of the...

Страница 7: ...backbar or underbar refrigerators designed for the cooling and storage of beverages The Mistral TC60 is a full height backbar refrigerator The following quantity of beverage bottles can be held in eac...

Страница 8: ...4 MISTRAL M60 M90 M135 AND TC60 MISTRAL DIMENSIONS M90 SD M60 M135 M90 TC60...

Страница 9: ...ed with glider feet which allow them to slide forward for cleaning and maintenance purposes The Mistral TC60 requires a clearance of 40 mm at the back of the unit The Mistral M135 is on castors to aid...

Страница 10: ...60 door Remove the grille cover by moving the cover upwards and then unhooking the lugs from the bottom of the cabinet Hold the door in its closed position to prevent the door from dropping when the h...

Страница 11: ...ndle Refit the door handle on the right hand side of the door and screw in the handle fasteners Apply one drop of Loctite Studlock 270 to the hinge pin thread Refit hinge pin on the left hand side of...

Страница 12: ...door making sure the hinge pin is inserted into the nylon bush which is in the worktop Refit the hinge and screw in the fasteners making sure the triangular spacer is clamped between the hinge and th...

Страница 13: ...the door lift the door upwards and swing the bottom out from the bottom roller guide Un hook the cable from the hook in the top of the door the door can now be fully removed from the unit Ensure the t...

Страница 14: ...d are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live COMMISSIONING Before using a bottle cooler for the first time the interior should be wiped out with...

Страница 15: ...closing at night or first thing in the morning to allow time for the bottles to cool Ensure that stock is rotated by placing new stock at the back of shelves or in one side of the cabinet to ensure t...

Страница 16: ...n be washed on the inside using bicarbonate of soda to remove stale smells CHANGING SHELF POSITION The shelves in all Mistral units are fully adjustable To adjust the shelves Remove the shelf Unclip t...

Страница 17: ...change the starter Open the front cabinet door s Ensure the light switch is in the off position The starter can be seen protruding through the light cover Rotate the starter anticlockwise and remove F...

Страница 18: ...strip light fitting To change the fitting Open the front cabinet door s Ensure the mains power to the unit has been turned off Slide the fitting to the left Pull the fitting out from the key hole slo...

Страница 19: ...ver is sooner Replace the grille cover M60 M90 M90SD and M135 Every three months switch off the unit and remove the contents to gain access to refrigeration service panel Remove the service panel and...

Страница 20: ...ate stock of bottles Don t Sit or stand on the unit worktop Don t Load with boxed goods Don t Leave the doors open Don t Cover the shelves with any protective materials which may obstruct air circulat...

Страница 21: ...ing the recovery of ozone depleting substances The unit must be sent to specialist recovery recycling and disposal site that is licensed for the disposal of refrigerated equipment Please note that the...

Страница 22: ...18 MISTRAL M60 M90 M135 AND TC60 M60 WIRING DIAGRAM...

Страница 23: ...MISTRAL M60 M90 M135 AND TC60 19 M90 M90SD WIRING DIAGRAM...

Страница 24: ...20 MISTRAL M60 M90 M135 AND TC60 M60 HIGH AMBIENT WIRING DIAGRAM...

Страница 25: ...MISTRAL M60 M90 M135 AND TC60 21 M90 HIGH AMBIENT WIRING DIAGRAM...

Страница 26: ...22 MISTRAL M60 M90 M135 AND TC60 M135 WIRING DIAGRAM...

Страница 27: ...MISTRAL M60 M90 M135 AND TC60 23 TC60 WIRING DIAGRAM...

Страница 28: ...24 MISTRAL M60 M90 M135 AND TC60 REAR VIEW SPARES GUIDE Compressor Condenser Drier Drip Tray Condenser Fan Refrigeration Assembly Evaporator...

Страница 29: ...MISTRAL M60 M90 M135 AND TC60 25 FRONT VIEW SPARES GUIDE Left Hand Door Right Hand Door Pilaster Strip Glide foot Controller Shelf Service Panel Evaporator Fan Door Handle Lock Door Gasket...

Страница 30: ...90 M135 AND TC60 FRONT VIEW SPARES GUIDE M90 SLIDING DOOR Evaporator Fan Controller Left Hand Door Rear Door Lock Glide Foot Right Hand Door Front Service Panel Shelf Pilaster Strip Door Runner Guide...

Страница 31: ...rip Tray G60 348 M1 Mains Cable G60 348 M1 Mains Cable G60 349 Mains cable EU plug G60 349 Mains cable EU plug S77 007 Refrigeration Pack S77 003 Refrigeration Pack S77 007 220 Refrigeration Pack 220V...

Страница 32: ...5 Plastic Drip Tray G42 045 Plastic Drip Tray G60 348 M1 Mains Cable G60 348 M1 Mains Cable G60 349 Mains cable EU plug G60 349 Mains cable EU plug S77 037 Refrigeration Pack HA S77 047 Refrigeration...

Страница 33: ...49 Mains cable EU plug G60 349 Mains cable EU plug S77 021 Refrigeration Pack S77 003 Refrigeration Pack S77 021 220 Refrigeration Pack 220V 60Hz S77 003 220 Refrigeration Pack 110V 60Hz S77 021 115 R...

Страница 34: ...0 Electronic Controller 115V G60 348 M1 Mains Cable G60 349 Mains cable EU plug S67 052 Refrigeration Pack S67 145 Door assembly E67 154 Door handle J09 025 Condenser G96 017 Condenser Fan Blade G96 0...

Страница 35: ...perial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Spares Fax 44 0 1978 667759 E mail service imco co uk E mail sales...