16 |
P a g e
FAULT FINDING
WARNING:
In the unlikely event of a fault occurring, immediately
isolate the power and water supplies.
If the appliance develops a fault, stop the machine immediately and isolate both the
electrical and water supplies.
In an
emergency situation only
, the emergency stop button should be used. This
is located on both front panels of the WasteStation AF and Remote Dewaterer.
Pressing the emergency button stops both machines instantly,
refer to important
notes in section 6.
NOTE: The emergency stop button should
only
be used to stop the machine in
an emergency. The red button found on the control box at the front of the
WasteStation AF should be used for routine stopping of the machine operation.
CLEARING A JAM
As a result of a jam occurring, the machine will stall and stop. If this occurs,
proceed as follows:
1.
Switch off
the machine at the mains or at the isolator switch on the rear panel.
2.
Unscrew the macerator lid.
3.
Engage the prongs of the release key into the vanes of the rotor and exert
pressure in either direction (i.e. clockwise & anti-clockwise) to free the
blockage.
4.
Check that the rotor is free to rotate 360
°
in both directions and if so, withdraw
the release key, screw down the macerator lid. (If there is still some resistance
when rotating, then repeat steps 3-4 until the jam is cleared).
5.
Restore power to the machine and check normal operation by pressing the
green button.