9 |
P a g e
WastePro II
ELECTRICAL CONNECTION
All electrical work must be carried out by a qualified electrician and in accordance with the IEE Codes
of Practice. Examine the rating plate located on the rear panel (next to the mains inlet) to ensure
that the characteristics shown are correct for the supply available. The supply cable fitted is the
minimum required for connection to the mains supply. Site conditions may vary with additional
length of cable run, encapsulation in trunking, bunched with other cables etc. Should this apply, the
electrician must alter the cable accordingly.
The WastePro II should be connected to a suitable 3-phase isolator providing at least 3mm
separation in all poles.
The mains supply cord - cable colours and cable markings are shown in the table below:
Warning: This appliance must be earthed.
If the supply cord becomes damaged it must be replaced by qualified electrician in order to avoid a
hazard.
Examine the rating plate attached to the machine to ensure that the characteristics shown are
correct for the supply available. The rating plate is located on the rear of the machine. The rating
shown is for the WastePro II itself , the overall rating will be higher depending on the rating of the
(existing) Macerator that is connected to the WastePro II and that should be taken into account for
the electricity supply
Sample Rating Plate
Phase
Cable Colour
Cable Marking
L1
Brown
L1
L2
Black
L2
L3
Grey
L3
Earth
Yellow/Green
None
Содержание F78/020
Страница 4: ...4 P a g e WastePro II MACHINE DIMENSIONS 820 980 452 150 MAX FOR SERVICES...
Страница 15: ...15 P a g e WastePro II WIRING DIAGRAM WASTEPRO II 400 VOLTS 3 PHASE...
Страница 16: ...16 P a g e WastePro II EXPLODED VIEW 1 1 2 3 4...
Страница 17: ...17 P a g e WastePro II EXPLODED VIEW 2 6 5 7 8 9...
Страница 18: ...18 P a g e WastePro II...
Страница 19: ...19 P a g e WastePro II EXPLODED VIEW 3 10 11 13 14 15 12...