F

I B E R

P

O R T

100

Glows yellow when a 100 Mbps connection is detected.

ACT

Glows green when activity is detected on the port.

LNK

Glows green when a fiber link is established.

L

I N K

F

A U L T

D

E T E C T I O N

L E D   A

C T I V I T Y

When LFD is enabled and a fault occurs on a segment of the media

conversion, the various Link LEDs in that conversion will either blink or
extinguish.  LEDs may react differently depending on the type of end
devices in the conversion, whether the McPC 10/100 is in 

Force 10

or

Force 100

mode, where the fault occurs, etc.  For questions, please contact

Technical Support.

IMC Networks Technical Support

Tel:

(

949)-465-3000; (800)-624-1070 (in U.S. and Canada)

+32-16-550880 (Europe)

Fax:

(

949)-465-3020

E-mail:

[email protected]

Web site:

www.imcnetworks.com 

Specifications

Environmental

Operating Temperature:  32° - 104° F (0° - 40° C)
Storage Temperature:  0° - 160° F (-20° - 70° C)
Humidity:  5 - 95% (non-condensing)
Current draw:  0.7A @ 5VDC

Power

Power Input: 5V

2

9

Configuring the McPC 10/100

Before installing, configure the McPC 10/100 using the DIP switch

located as shown below on the printed circuit board (PCB).  The following
illustration shows the location of the DIP switch as well as its default
settings.  Consult the chart below for the function of each switch. 

The table below shows the DIP switch settings for McPC 10/100:

N O T E

Twisted pair AND fiber optic cables must be connected, and the twisted pair
crossover/pass-through switch set correctly, before either LNK LED will glow solid.

F

EATURE

S

WITCH

#

F

UNCTION

D

EFAULT

LFD

5

Link Fault Detection (Available in Force modes only)

OFF

AN

6

Auto-Negotiation Mode (Valid only when Force
mode is disabled)

ON

Force

7

Force Mode — Forces the converter to operate at
10 or 100 Mbps as determined by switch 8

OFF

10/100

8

When  ON, the converter operates at 10 Mbps. 
When OFF, the converter operates at 100 Mbps.
is only valid in Force Mode, i.e. when switch is
ON

OFF

Note: Switch #’s are factory configured — DO NOT CHANGE

Содержание McPC 10/100

Страница 1: ...McPC 10 100 Operation Manual...

Страница 2: ......

Страница 3: ...rency 5 Link Fault Detection 6 Installation 7 Twisted Pair Crossover Pass Through Button 8 LED Indicators 8 Technical Support 9 Specifications 9 Fiber Optic Cleaning Guidelines 10 Warranty 10 Federal...

Страница 4: ......

Страница 5: ...below shows the DIP switch settings for McPC 10 100 FEATURE SWITCH FUNCTION DEFAULT LFD 5 Link Fault Detection Available in Force modes only OFF AN 6 Auto Negotiation Mode Valid only when Force mode...

Страница 6: ......

Страница 7: ...as switches hubs and repeaters all devices in the media conversion should ideally support and be utilizing Auto Negotiation functionality While it is possible to have auto negotiating devices on one s...

Страница 8: ......

Страница 9: ...rface to the McPC 10 100 is also down there is no output LFD causes the Link Up indicator of the link partner to blink When the McPC 10 100 is in one of the Force modes enable LFD by setting 5 to the...

Страница 10: ......

Страница 11: ...e twisted pair LNK link LED glow LED Indicators The McPC 10 100 features several diagnostic LEDs per port The LED functions are as follows T W I S T E D PA I R P O R T L Glows green when a twisted pai...