Specifications
Operating Temperature*
32° to 122°F (0° to +50°C); 5% to 90% (non-condensing), 0 to 10,000 ft. altitude
Storage Temperature*
-13° to +158°F (-25° to +70°C); 5 to 90% (non-condensing)
*Some products may support lower operating and storage temperatures.
Electrical
MediaConverter/1
AC Input Load: 100/240 100-240VAC ±10% , 50/60Hz, 0.1/0.05A 0.3A
Maximum Heat Generated: 51 BTU/hour
MediaConverter/4
AC Input Load: 100/240 100-240VAC ±10% , 50/60Hz, 0.1/0.05A 1.2A
Maximum Heat Generated: 67 BTU/hour
MediaConverter/8
AC Input Load: 100/240 100-240VAC ±10% , 50/60Hz, 0.5/0.2A 1.2A
Maximum Heat Generated: 137 BTU/hour
MediaConverter/12
AC Input Load: 100/240 100-240VAC ±10% , 50/60Hz, 0.5/0.2A 1.2A
DC Input Load: -48 ±10% VDC, 1A
Maximum Heat Generated: 137 BTU/hour for AC unit, 171 BTU/hour for DC unit
Dimensions
MediaConverter/1
H=1.6” x W=4.8” x D=4.5” (4 x 12.1 x 11.5 cm)
MediaConverter/4
H=1.7” x W=9.1” x D=5”
(4.4 x 23.1 x 12.6 cm)
MediaConverter/8
H=1.7” x W=17.4”x D=5”
(4.4 x 44.2 x 12.8 cm)
MediaConverter/12
H=1.7” x W=19” x D=9”
(4.4 x 48.3 x 22.9 cm)
Electrostatic Discharge Precautions
Electrostatic discharge (ESD) can cause damage to your add-in modules. Always
observe the following precautions when installing or handling an add-in module or
any board assembly.
1.
Do not remove unit from its protective packaging until you’re ready to install it.
2.
Wear an ESD wrist grounding strap before handling any module or component.
If you do not have a wrist strap, maintain grounded contact with the system unit
throughout any procedure requiring ESD protection.