The switch has two settings.
OFF
is the normal operating position and
ON
is the
locked position.
IMPORTANT USAGE INFORMATION
Leave the SNMP Write Lock switch in the
OFF
position during day-to-day operation.
ONLY move the switch to the
ON
position when changing the SNMP management
board.
The SNMP management module can be removed and replaced when necessary. A
saved firmware file can be uploaded to the second SNMP module to retain
configuration settings. Make sure that the SNMP Write Lock switch is set to the
ON
position. Save the firmware file periodically in case there is a need to replace the
SNMP management module (refer to the
About Serial Port Configuration
section for
more information).
When the management module is removed while the SNMP Write Lock switch is set
to
OFF
, the application module configurations revert to dip switch settings. Make
sure the dip switches are set to the same configuration as the SNMP management.
Re-installing the same management module will return the application modules to the
SNMP management configuration. Installing a new management module when the
switch is set to
OFF
will cause the installed application modules to use the
management settings of the new module. Make sure to always reconfigure
application modules when moving them from one chassis to another.
Using the SNMP Write Lock Switch
To lock the SNMP module settings by using the SNMP Lock Switch, perform the
following:
1.
Set the SNMP Write Lock switch to
OFF
.
2.
After configuring all application module settings by using SNMP, use iConfig to
make a backup copy of the SNMP management module firmware.
NOTE
These first two steps are typically performed during initial installation.
3.
To replace the SNMP management module, first set the SNMP Write Lock
switch to
ON
.
4.
Remove the old SNMP management module and replace it with another SNMP
module.
5.
Access the SNMP management module using iConfig. Select the
Administration
tab and click on
List Tasks
. Highlight
Flashsav
and click the
Terminate
button.
6.
Update the new board with the firmware backup made in step 2.
8