background image

 

 

iMediaChassis/3 

Operation Manual 

 

 

Содержание iMediaChassis/3

Страница 1: ...iMediaChassis 3 Operation Manual ...

Страница 2: ...r To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be accepte...

Страница 3: ...6 Installing Management Modules 7 Connecting Chassis and Modules 7 Configuring an SNMP Management Card 7 SNMP Write Lock 9 Using Telnet 9 About DHCP 10 About iConfig 10 About Serial Port Configuration 15 Before using iView 15 Installing and Using iView 16 Power Supply 17 Temperature Control 18 Specifications 18 IMC Networks Technical Support 19 Safety Certifications iii ...

Страница 4: ...gement module is removed The iMediaChassis 3 can also hold two double wide iMcV modules when there is no SNMP management card in the management slot Double wide modules with built in management such as the iMcV Giga FiberLinX II can be managed in the chassis without the need for an SNMP module in the management slot The power supply configurations available for the iMediaChassis 3 include the foll...

Страница 5: ...he power load Refer to the Power Supply and Temperature Control sections for wiring alarm and Trap information NOTE The iMediaChassis 3 power supply is not field replaceable Installing Application Modules Refer to the module installation guide for configuration information To install a module remove the faceplate if present covering the slot where the module will be installed Double wide modules w...

Страница 6: ...ion modules such as media conversion and mode conversion modules in this slot Double wide modules installed in Slot 1 will overlap the management slot SNMP Management Module LEDs Each SNMP Management Module features several LEDs The LED functions are LNK ACT Glows green when a link is established on port Blinks green when data activity occurs FDX COL Glows amber when port is in Full Duplex mode Bl...

Страница 7: ...uration information e g IP address subnet mask etc You can assign the IP information by using one of the following iConfig The management module serial port DHCP Dynamic Host Control Protocol DHCP must be enabled through serial configuration You can also create community strings assign access rights configure Traps and more Using iConfig allows more Trap and MIB access configuration options than w...

Страница 8: ... Re installing the same management module will return the application modules to the SNMP management configuration Installing a new management module when the switch is set to OFF will cause the installed application modules to use the management settings of the new module Make sure to always reconfigure application modules when moving them from one chassis to another Using the SNMP Write Lock Swi...

Страница 9: ... Telnet session at the same time NOTE A Telnet session uses the same password as the iConfig application About DHCP There is a DHCP client in the iMediaChassis 3 By default the DHCP client is disabled If a DHCP server is present on the network and DHCP is enabled the DHCP client will initiate a dialogue with the server during the boot up sequence The server will then issue an IP address to the iMe...

Страница 10: ...ble as a standalone application as well as built in to the Windows version of iView Windows 98 users must use the standalone version of the iConfig utility Both applications are included on the iView CD Refer to the iConfig utility online help file for more information about the iConfig utility About Serial Port Configuration The SNMP management module used with the iMediaChassis 3 features a seri...

Страница 11: ...tinations s Press C to enter new Community String Press U to remove ALL Community String reboot unit Press D for DHCP On Off Press E to End session Type REBOOT to Press SpaceBar for additional commands Saved Values displays changes made during current session IP Address MUST be assigned during initial configuration Subnet Mask MUST be assigned during initial configuration Default Gateway Server IP...

Страница 12: ... a network The default community string is named public and has read write access Delete the public string and add necessary custom community strings such as one with read only access for general use the other with read write access for the administrator To create a new community string go to the main configuration screen and press C Enter the name of the new community up to 16 characters no space...

Страница 13: ...and press Enter This password will be requested whenever logging on To remove password protection select P and instead of entering a password press Enter It is the responsibility of the network administrator to store and maintain the password lists If passwords are lost neither the end user nor IMC Networks can retrieve them Enabling Disabling DHCP To Enable Disable DHCP press D Then type reboot f...

Страница 14: ...irmware downloads from a central server by using TFTP protocol Use serial configuration or a Telnet session to perform this download Make sure the IP Address and the name of the file are correct in the Current Values section of the Main Configuration screen If this information is not correct make the appropriate changes To download a file press the Space Bar from the Command List section of the Ma...

Страница 15: ...gher not required as default browser Microsoft IIS required for Web Server version Java versions require the following 25 MB free disk space 64 MB RAM Any OS capable of running Java Windows 98 or above Solaris LINUX Java Runtime v 1 3 Strongly recommended 128 MB RAM Pentium III 650Mhz or Faster 17 Monitor 1024 x 768 Resolution or higher Installing and Using iView Please consult the iView CD for in...

Страница 16: ...2C MIB Refer to the management software documentation for information on how MIB files are integrated into the software Power Supply The iMediaChassis 3 ships with one or two AC or DC power supplies or one of each depending on the model DC Power Supply Wiring Instructions The following image shows the wiring configuration for a Telco application of 48 VDC power supply for the iMediaChassis 3 NOTE ...

Страница 17: ...ture Trap to protect the chassis from overheating Temperature Triggered Fans The iMediaChassis 3 includes temperature triggered fans When the temperature of the chassis reaches 40 C the two fans are activated You can test the fans operation by holding the Alarm Reset button down for 4 to 5 seconds The fans will activate and then they will turn off when you release the button If the fans do not act...

Страница 18: ...re 0 to 160 F 20 to 70 C Humidity 5 to 90 non condensing 0 to 10 000 ft altitude Dimensions H 1 73 W 7 50 D 8 74 4 4 x 19 0 x 22 0 cm Heat Output 171 BTUs IMC Networks Technical Support Telephone 949 465 3000 Toll Free 800 624 1070 U S A and Canada Europe 32 16 550880 FAX 949 465 3020 E Mail techsupport imcnetworks com www imcnetworks com Web Site 18 ...

Страница 19: ... WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local autho...

Страница 20: ...tice IMC Networks assumes no responsibility for any errors that may appear in this document iMediaChassis 3 is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 50 80949 00 A0 November 2006 If the product s part number begins with an 8 it is compliant with the Restriction of Hazardous Substances RoHS direc...

Отзывы: