The iMcV-T1/E1/J1-LineTerm module features several diagnostic LEDs per port.
The following LED display functions are provided:
Copper Port LEDs
ER
Flashes yellow whenever a line code violation is
received.
LOS
Glows red when the RJ-48 is receiving no signal and is
in an LOS ALARM state. This condition will also send
an RAI signal to the fiber port. If the Fault Loopback is
set to ON, an AIS will also be sent to the local copper
port.
PRBS
Glows green when the copper port receives a valid
Pseudorandom Bit Sequence (PRBS). It is OFF when
the port is not receiving a PRBS.
TEST
Glows yellow when any Loopback mode is active.
Fiber Port LEDs
ER
Glows yellow when a fiber symbol error has been
received.
LOS
Glows red when a fiber link is not established and is in a
LOS ALARM state.
RM
Glows green on the Remote Unit when set to DSW S3-
2. Glows green on the Local unit when it has
discovered a Remote management with Remote Unit
enabled.
RAI
Glows
yellow when a Remote Alarm Indication (RAI) is
received on the fiber port. This indicates a fault exists at
the far end unit.