2

 

Managed Modules 

To manage one or more IE-iMcV-MediaLinX TX/SFP Modules, an SNMP agent must 
be present in the chassis:  The iMediaChassis series requires an SNMP Management 
Module.  To configure Managed Modules, install the module first, and then configure 
using the management software. Module Details will provide information such as 
serial number, date code and part number as well as product-specific features.  

Configuration Control 

Some iMcV-Modules offer Configuration Control; labels on the front faceplate are 
identified as such. Configuration Control has been implemented to assist the end user 
by retaining the latest configuration regardless of how that configuration was 
implemented (via DIP Switch settings or SNMP). 

Historically, SNMP would override DIP Switch settings. If changes are made via DIP 
Switch settings, then hardware settings determine the configuration of the board.  If 
changes are made to the module via iView

2

, the SNMP settings determine the 

configuration of the board. 

 
Utilizing Configuration Control, the end user has three conditions under which the 
configuration of the iMcV-Module may be impacted: 

 

Installing an 

IE-iMcV-MediaLinX TX/SFP

 into a chassis already loaded with iMcV-

Modules or replacing an 

IE-iMcV-MediaLinX TX/SFP

 

The iMcV-Module will transfer its saved configurations. The 

IE-iMcV-

MediaLinX TX/SFP

 will not override the module’s configuration. 

 

Replacing the same type of iMcV-Module 

If the DIP Switch settings are the same as the settings on the removed iMcV-
Module, the IE-iMcV-MediaLinX TX/SFP determines the configuration 
settings. 

If the DIP Switch settings are different, then the configuration of the module 
is determined by the DIP Switch settings. (The settings are forwarded to the 
IE-iMcV-MediaLinX TX/SFP and the value is saved.) 

 

Installing a new model of iMcV-Module 

If another type of module is installed into the same slot in a chassis, the IE-
iMcV-MediaLinX TX/SFP clears the memory of the previous configuration 
for that slot; the settings of a new module are adopted and stored in the IE-
iMcV-MediaLinX TX/SFP. 

 
 
 
 
 

Содержание IE-iMcV-MediaLinX TX/SFP

Страница 1: ...IE iMcV MediaLinX TX SFP iMcV MediaLinX TX FX Operation Manual ...

Страница 2: ...nger To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be acce...

Страница 3: ...LinkLoss TX LinkLoss Link Fault Pass Through FiberAlert and Far End Fault 4 Link Fault Pass Through LFPT 5 Auto Negotiation on IE iMcV MediaLinX TX SFP 7 Additional IE iMcV MediaLinX TX SFP Features 8 LED Operation 9 Installation Troubleshooting 10 Specifications 10 IMC Networks Technical Support 10 Fiber Optic Cleaning Guidelines 11 Electrostatic Discharge Precautions 11 Certifications 12 ...

Страница 4: ... range of 40C to 85C when installed in an IE MediaChassis 1 or 2 Available in AC and DC the module can be installed in challenging heat or cold related environments Installing an iMcV Module iMcV Modules install in IMC Networks SNMP manageable iMediaChassis series or in any MediaChassis IE MediaChassis series To install an iMcV Module 1 Remove the blank bracket covering the slot where the module i...

Страница 5: ...2 the SNMP settings determine the configuration of the board Utilizing Configuration Control the end user has three conditions under which the configuration of the iMcV Module may be impacted Installing an IE iMcV MediaLinX TX SFP into a chassis already loaded with iMcV Modules or replacing an IE iMcV MediaLinX TX SFP The iMcV Module will transfer its saved configurations The IE iMcV MediaLinX TX ...

Страница 6: ... as well as Configuration Control iMcV Modules it is important to understand how SNMP and DIP Switches will impact the cards depending on their capability Standard iMcV Modules cannot be upgraded to Configuration Control capability so it is strongly recommended to set the DIP Switches on the modules and then configure them via software to match the same settings Unmanaged Modules Before installing...

Страница 7: ...ices When an IMC Networks media converter receives valid link pulses it knows that the device to which it is connected is up and sending pulses and that the copper or fiber cable coming from that device is intact The appropriate LNK link LED is lit to indicate this The IMC Networks media converter also sends out link pulses from its copper and fiber transmitters but normally has no way of knowing ...

Страница 8: ...dia converter is not receiving a twisted pair link TX LinkLoss disables the transmitter on the media converter s fiber port This results in a loss of link on the device connected to the fiber port and the TXLL LED will blink Link Fault Pass Through LFPT Link Fault Pass Through LFPT is a troubleshooting feature that combines TX and FX LinkLoss from both the local and remote IE iMcV MediaLinX TX SFP...

Страница 9: ...efinitely Far End Fault By default FEF is disabled When enabled and a fault occurs on the fiber line affecting data in one direction an FEF signal will be sent in the opposite direction indicating the fault FXLL will act on this signal propagating the loss of link to the copper port when FXLL is enabled FEF versus FA FEF is preferred when the devices at both ends of the fiber can interpret the FEF...

Страница 10: ... MediaLinX TX SFP IE iMcV MediaLinX TX SFP modules include the feature Auto Negotiation When Auto Negotiation is enabled the module negotiates as a 10 100 Mbps full duplex device If the connected device can operate at 100 Mbps full duplex a link is established Auto Negotiation DIP Switch 1 is enabled by default If the twisted pair port on the other device does not have the ability to Auto Negotiat...

Страница 11: ...e fiber port If the copper port is supporting PAUSE due to the outcome of the Auto Negotiation process then congestion on the copper port will cause PAUSE frames to be sent out the fiber port In a like fashion if congestion occurs on the fiber port then the copper port will send PAUSE if flow control is enabled on the copper port through the outcome of Auto Negotiation In half duplex mode the unit...

Страница 12: ...vely disables the fiber port 100 Glows yellow when 100 Mbps is selected on port LNK ACT Glows green when a link is established on port Blinks green when data activity occur FDX COL Glows yellow when port is in Full Duplex Mode Blinks yellow when modules are being operated in Half Duplex Mode and collisions occur Fiber Optic LEDs FXLL Glows green when FX LinkLoss is enabled Blinks when a fault occu...

Страница 13: ... a short distance installation the fiber transmitters may overdrive the receivers and cause data loss If this is the case an optical attenuator may need to be added to the connection For fiber specifications visit the IMC Networks Web site at www imcnetworks com adocs fcs asp or contact IMC Networks for more information Specifications Environmental Operating Temperature IE 40 F to 185 F 40 C to 85...

Страница 14: ...between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective...

Страница 15: ...of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about proper...

Страница 16: ...information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE iMcV MediaLinX TX SFP is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 56 80912 00 B1 July 2010 ...

Отзывы: