Appendix B
Servicing
152
Power Supply Replacement (X100-PSU-200W)
The X100 includes two power supplies. In the event of a power supply failure, follow these
steps to remove and replace the unit:
1
Remove the top cover, as described on page 148, ensuring
both
AC power cords are
unplugged.
2
Remove the input and output connectors of the failed power supply by squeezing the tab
on the connectors and separating the connectors from the power supply (
3
Remove and save the four power supply mounting screws, and lift out the power supply
unit.
Figure B-8.
Power Supply Removal
4
Install the new power supply using the screws provided, and re-attach the connectors.
5
Reverse the steps found in
Remove four screws.
Separate the input
and output power
supply connectors.
Содержание Selenio X100
Страница 8: ...Selenio X100 Installation and Operation Manual viii...
Страница 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Страница 22: ...Selenio X100 Installation and Operation Manual 10...
Страница 38: ...Selenio X100 Installation 26...
Страница 158: ...Appendix A Laser Safety Guidelines 146...
Страница 178: ...166...