Selenio X100
Installation and Operation Manual
131
SDI Optical Dual Receiver
Table 5-16
OP+SFP+RR Dual Input Fiber Specifications
Item
Minimum
Typical
Maximum
Notes
Number of LC Input Connectors
-
-
2 X 2
Standards
3G: SMPTE 424M
HD-SDI: SMPTE 292M
SD-SDI: SMPTE 259M
Input Wavelength
1260 nm
-
1620 nm
Optical Power Monitor Accuracy
-2 dB
-
2 dB
Sensitivity at 270 Mb/s (SMPTE 259M)
-
-22
-20
Pathological*
Sensitivity at 1.5 Gb/s (SMPTE 292M)
-
-22
-20
Pathological
Sensitivities at 3 Gb/s (SMPTE 424M)
-
-20
-18
Pathological
Overload
0 dBm
-
-
2.97 Gb/s*
Laser Safety Level
Class 1
*BER = 1E-12 against SDI matrix. Check field signals for video applications. BER = 1E-12 against PRBS 223-1 for datacom applications.