852-GS Ultra-Miniature Imaging Sonar
Doc No: 430-048-0B
Page
15
of
34
2.3.2.
File Playback
Table 3 Playback Control
The file playback bar is used during playback and allows the user to adjust the playback speed and file
position.
2.3.3.
Sonar Settings
The sonar settings toolbar is used to control various sonar attributes. It is only available in RealTime mode:
Figure 3 Sonar Settings
•
Range
: Sets the maximum range of target detection. 5 - 50 m
•
Gain
: Sets the sonar gain. 0 - 40 dB. Adjust until the display is optimized for the target environment
•
Sector
: Defines the scan sector (0°
– 360° in 3° increments)
•
Train
: Allows for the rotation of the sector (set above) around the centre (0°
– 360° in 3° increments)
•
Speed
: Defines the scan speed of the sonar. (Slow
– Fastest)
•
Mode
: Sets Polar, Sector, or Side Scan mode, as described in 3.2.7. View => Grid
•
Enable ES
: Click if echo sounder available. Displays echo sounder window
•
Range
: Sets the echo sounder range. Ranges from 5 m to 50 m are available
•
Gain
: Sets the echo sounder gain. Max 40 dB. Adjust until the display is optimized for the target
environment