Using the Controls

Air Control 1:

Determines the amount of air flowing

through the hydrotherapy jets labeled 1 (above). If the

control is turned counterclockwise, the amount of air

will increase; if the control is turned clockwise, the

amount of air will decrease. Air controls 2–4 function

in the same manner.

Air Controls 2, 3, and 4:

Determine the amount of air

flowing through the hydrotherapy jets labeled 2, 3,

and 4 (above).

Display Invert Button:

Turns the display 180°, allow-

ing it to be read from inside or outside of the spa.

Pump Button 1:

Turns the spa jets labeled 3 and 4

(above) on and off. If the button is pressed once, the

jets will run on low. If the button is pressed a second

time, the jets will run on high, providing gentle

hydrotherapy. If the button is pressed a third time, the

jets will shut off.

Pump Button 2:

Turns the spa jets labeled 1 and 2

(at the left) on and off. If the button is pressed once,

the jets will run, providing soothing hydrotherapy. If

the button is pressed again, the jets will shut off.

The spa also features an automatic mode that heats

and filter the water when the spa is left unattended.

When the power to the spa is first turned on, or if the

water temperature is below the set temperature, the

water will be heated as required.

Note: To keep the

filter and heat cycles from running, the power to

the spa must be turned off.

Light Button:

Turns the underwater light on and off.

Temperature Buttons:

Control the temperature setting

of the water. The temperature setting can be from

80°F to 104°F. The water heats at about 6°F per hour

with the cover on. Use a medical or other accurate

thermometer to check the temperature of the water.

Note: The word “COOL” will appear in the console

display if the temperature of the water is more than

20°F cooler than the set temperature. When this hap-

pens, the heater will automatically activate to warm the

water. The word “ICE” will appear in the display if the

temperature drops below 40°F. If this happens, the

pump will automatically circulate the water and warm

the plumbing to keep the water from freezing.

Air Control 4

Air Controls

1, 2, and 3

Light

Button

Pump

Button 1

Pump

Button 2

Display

Display

Invert Button

1

2

1

1

2

3

4

4

1

3

3

4

Temperature

Buttons

Содержание IMSB63920

Страница 1: ...provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMSB63920 IMSG63920 Serial No The serial number is on a sign behind the access panel Writ...

Страница 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Страница 3: ...nt damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa t...

Страница 4: ...eir physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important du...

Страница 5: ...SE INSTRUCTIONS water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the...

Страница 6: ...el your best For your benefit read this manual carefully before using the IMAGE RENEW 639 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877...

Страница 7: ...he spa provided you leave access to the motor for service 9 Make sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Страница 8: ...During assembly make sure that all parts are oriented as shown in the drawings Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBL...

Страница 9: ...drotherapy spa operates on a 240 volt power source and must be wired directly to a 40 amp ground fault circuit interrupter GFCI installed in your home This procedure must be performed by a qualified e...

Страница 10: ...intenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the pump button 1 on the console see USING THE CONTROLS on p...

Страница 11: ...stalled to utilize the ozone jet Ozone helps sani tize the spa with minimal chemical treatment H The console controls the spa jets turns the under water light on and off and adjusts the water tem pera...

Страница 12: ...ff The spa also features an automatic mode that heats and filter the water when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set tem...

Страница 13: ...d a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone based vinyl conditioner on the cover after you c...

Страница 14: ...can be adjusted to last 2 to 5 hours Press the temperature up or temperature down button on the console When the display begins to flash press the pump button The display will read F2 To change the ti...

Страница 15: ...he spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest setting...

Страница 16: ...the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the w...

Страница 17: ...ce the damaged seal b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact y...

Страница 18: ...Bolt 29 1 Console with Overlay 30 8 1 4 Lock Washer 31 8 1 4 Washer 32 1 Face Plate Assembly 33 3 Long Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet 36 4 Nozzle Housing 37 20 Small Rotator 38 1...

Страница 19: ...4 36 40 39 41 42 41 38 35 46 46 46 46 33 47 7 8 54 52 53 53 50 23 19 28 30 31 13 6 45 48 30 31 4 13 10 28 30 31 13 6 45 48 30 31 4 13 9 14 9 9 49 49 34 34 17 17 17 17 55 51 5 22 3 21 16 24 32 Exploded...

Страница 20: ...e following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulti...

Отзывы: