background image

9

5. Remove the two warning decals (not shown) from

the spa shell. Using a damp cloth, wipe the spa shell
clean. Before filling the spa, make sure that it is
in the desired position and that there is room to
service the spa. Once the spa is filled, it will
have to be drained before it can be moved.

Insert a garden hose into the filter housing, and
begin filling the spa. Do not use soft water. The
spa may be filled with cold water; however, if warm
or hot water is used, the spa will be ready for use
sooner. Fill the spa until the water is at the level of
the molded fill line. Do not overfill the spa.

Refer to the inset drawing. Set the Filter (16) in the
filter housing. Screw the Filter Cover (8) into the filter
housing until it is fully seated.

4. The spa operates on a 240-volt power source and must be wired directly to a 30 amp Ground Fault Circuit

Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed
electrician. A wiring diagram has been provided on the inside of the electronics package as a reference.
Under no circumstances should the spa be wired by someone other than a qualified electrician. 
Before
you have the spa wired, make sure that it is in the desired position and that it can be serviced, if needed.

6. Pull down one of the straps on the Spa Cover (11)

and hold the Buckle (30) against one of the cedar
panels on the spa. (Note: To position the Buckle cor-
rectly, have a second person hold the strap on the
opposite side of the Spa Cover tight.) The Spa
Cover must be tight. Do not place the Buckle
over the grooves between the cedar panels. 
Refer
to the inset drawing. Remove the latch from the
Buckle (30). Attach the Buckle to the cedar panel
with two #4 x 3/4” Screws (31).

Attach the other three Buckles (30) to the cedar pan-
els in the same way.

Remove the Spa Cover (11) from the spa.

5

Water

Level

Filter

Housing

6

11

30

Strap

Strap

Latch

30

31

8

16

Filter

Housing

3. Locate the three pillows. Each pillow can be

attached to the spa shell in a high position or a low
position. To determine the high and low positions,
attach one pillow to the spa shell, note its position,
remove it, turn it 180°, and then re-attach it. Attach
the three pillows in the desired positions.

3

Pillow

Pillow

Pillow

Содержание IMSB61610, IMSG61610

Страница 1: ...immediate assistance CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future ref...

Страница 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Страница 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Страница 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seri...

Страница 5: ...ll users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on th...

Страница 6: ...t you need to feel your best For your benefit read this manual carefully before using the RENEW 616 If you have questions after reading the manual call our Customer Service Department toll free at 1 8...

Страница 7: ...spa provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Страница 8: ...of metal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two page...

Страница 9: ...ectronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that it is in the desired position...

Страница 10: ...proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE...

Страница 11: ...ble directional jets can be pivoted to direct the water flow G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with mi...

Страница 12: ...drotherapy If the button is pressed twice the spa jets will run at high speed providing moderate pres sure hydrotherapy If the button is pressed again the jets will shut off The spa also features an a...

Страница 13: ...p solution do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water an...

Страница 14: ...testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 5 hours Press the temp up or temp down button o...

Страница 15: ...1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest...

Страница 16: ...main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See th...

Страница 17: ...MPTOM NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTER CLOCKWISE a If no air flows through the hydrotherapy jets when the air control is turned counterclock...

Страница 18: ...ber Washer 30 4 Buckle 31 8 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Filter Cover O ring 34 2 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 4 Nozzle Retainer Ring 38 4 1 4 Washer 39 1 Rotator 4...

Страница 19: ...6 26 30 31 21 27 28 13 20 11 2 7 25 26 10 18 17 13 9 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 18 19 24 51 5 1 8 16 33 14 9 9 52 52 19 53 54 Exploded Drawing Model No IMSB61600 IMSG6160...

Страница 20: ...llowing incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting fro...

Отзывы: