Image 831.105150 Скачать руководство пользователя страница 3

3

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJURY, READ

THE FOLLOWING IMPORTANT PRECAUTIONS BEFORE USING THE RENEW 515.

READ AND FOLLOW ALL INSTRUCTIONS

1. It is the responsibility of the owner to ensure

that all users of the hydrotherapy spa are

adequately informed of all precautions.

2. Use the hydrotherapy spa only as described

in this manual.

3. The hydrotherapy spa is intended for home

use only. Do not use the spa in any commer-

cial, rental, or institutional setting.

4. Use the hydrotherapy spa only on a level

surface. Do not use the spa on carpet or

other materials that could be damaged by

moisture. Do not use the spa on rough or

sharp surfaces such as gravel or wood

chips.

5. The hydrotherapy spa will weigh approxi-

mately 2,000 pounds (908 kgs) when it is

filled with water. Be sure that the location

you select for the spa will support this

weight, plus the weight of the occupants.

6. Inspect and tighten all parts regularly; replace

any worn or missing parts immediately.

7. DANGER—Risk of injury: Do not remove or

alter the covers on the suction fittings. Never

operate the hydrotherapy spa if the suction

guard is missing or broken. If you need to

replace a suction fitting, be sure to use only

manufacturer-recommended parts. Keep hair

and body parts away from the suction guard.

Do not allow long hair to float freely in the

water; long hair should be restrained with a

bathing cap.

8. IMPORTANT: Do not allow the hydrotherapy

spa to be exposed to direct sunlight when it

is empty. The surface of the spa shell can

reach temperatures as high as 150°F (65°C)

in a matter of minutes if exposed to the sun

while it is empty. These high temperatures

can cause significant damage, such as blis-

tering of the shell surface and warping of the

spa shell. Any damage caused by sun expo-

sure is not covered under warranty.

9. Do not bring any object into the hydrothera-

py spa that could damage the spa shell.

10. Never insert any object into any opening.

11. Do not use breakable containers near or in

the hydrotherapy spa.

12. Do not sit on the spa cover or place objects

on it. It is not designed to support weight.

13. Remove any water or debris that may collect

on the spa cover.

14. Keep children under 12 and pets away from

the hydrotherapy spa when it is not in use.

15. Keep all chemicals away from children and

pets.

16. The pH and chemical balance of the water

must be maintained as explained in this man-

ual (see pages 11 and 16). Failure to do so

may cause injury to users or damage to the

spa, and it will void the warranty.

17. Individuals with infections and open sores or

wounds should not use the hydrotherapy

spa. Bacteria thrive in warm and hot water.

Always keep the spa disinfected and main-

tain the proper chemical balance.

18. Shower before and after using the hydrother-

apy spa. This will remove any deodorant,

perspiration, or body oils that could contami-

nate the water. Showering after will remove

any residual chemicals and any bacteria that

may have been in the spa.

19. WARNING—The Ground Fault Circuit

Interrupter (GFCI), must be tested before

each use. To test the GFCI, press the “test”

button while the hydrotherapy spa is run-

ning. The spa should shut off. Press the

“reset” button. The spa should resume nor-

mal operation. If the spa continues to run

after the “test” button is pressed, then the

GFCI is damaged. Do not use the spa until

the GFCI has been repaired or replaced by a

qualified electrician.

Содержание 831.105150

Страница 1: ...The trained technicians on our customer hot line will provide immediate assistance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No 831 105150 Serial No Write th...

Страница 2: ...ishandling damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or da...

Страница 3: ...of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blis tering of the shell surface and warping of the spa shell Any damage caused by sun...

Страница 4: ...r below Lower temperatures are also recommended for chil dren Children should not be allowed to swim under the surface of the water in the spa 26 WARNING To reduce the risk of injury Always use an acc...

Страница 5: ...erminalmarked G GR Ground Grounding or with the symbol is located inside the supply terminal box or compartment To reduce the risk of electric shock this terminal must be connected to the grounding me...

Страница 6: ...ughout the body The RENEW 515 gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the RENEW 515 If you have addi tional...

Страница 7: ...ble with a deck system that is built flush with the top of the spa provided you leave access to the motor for servic ing 8 Make sure to note any other considerations such as aesthetics or privacy conc...

Страница 8: ...information on the previous two pages Remove the four cover screws from the access cover Remove the access cover from the Spa Unit 15 by sliding the access cover down and pulling the bottom of the acc...

Страница 9: ...rawing Remove the latch from the Buckle 2 Attach the Buckle to the wood panel with two Buckle Screws 1 Note It may be helpful to use a drill with a 1 16 bit to make starter holes in the wood panel It...

Страница 10: ...ce where it will be visible to all users of the RENEW 515 Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Custo...

Страница 11: ...you refill the spa Once you have verified that the spa is functioning properly and the water has cir culated for a while remove the spa cover and add 1 3 of the Bromine Base bottle and 1 3 of the Non...

Страница 12: ...spa is ozone ready An optional ozone generator can be installed to utilize the ozone jet C Ozone provides a way to help sanitize your spa with minimal chemical treatment The suction vents D near the...

Страница 13: ...e The thera jets will operate at full speed To turn the pump on low press the button again The thera jets will operate at low speed After you press the button a third time the thera jets will shut off...

Страница 14: ...ngth of the cycle press the light and up buttons at the same time The length of the cycle will appear in the temperature display Press the up and down buttons to select the desired cycle length Note T...

Страница 15: ...the wood panel exterior twice a year with an additional coat of weather sealant Contact your local spa and pool supplier for advice on which sealants work best in your climate CLEANING THE SPA SHELL...

Страница 16: ...d 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with y...

Страница 17: ...s Push the handles into the closed position and turn the handles until they lock into place If you are planning to work on the pump or motor you will also need to drain the pump see this page To open...

Страница 18: ...e filter door Removing and Cleaning the Filter Cartridges 1 Follow steps 1 through 4 at the left to remove the basket 2 Reach into the housing and locate the plastic diverter on top of the filter cart...

Страница 19: ...TENANCE NOTES Maintenance is an important part of keeping your spa in top operating condition Use the space below to make any notes you may want to remember for future reference or to keep a maintenan...

Страница 20: ...the spa cover The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water will heat at 2 F 1 C per hour If you are using the spa...

Страница 21: ...PA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the spa jets on high press the Pump button once To turn the spa jets on low press the control twice To turn the spa jets off press the control...

Страница 22: ...Screw 20 2 Small Index Nut 21 1 Adjustment Bracket 22 1 Hose Washer 23 2 Small Bracket Screw 24 1 Sensor Fitting 25 6 Multidirectional Jet 26 1 Red Lens Key No Qty Description 27 1 1 2 O ring 28 1 Con...

Страница 23: ...1 2 2 6 9 14 15 16 17 18 32 31 29 30 25 26 8 19 19 8 8 7 24 19 4 5 13 11 27 33 37 36 35 25 34 21 3 23 23 20 28 22 EXPLODED DRAWING Model No 831 105150 R0400A 23...

Страница 24: ...excluding holidays To help us assist you please be prepared to give the following information when calling The MODEL NUMBER of the product 831 105150 The NAME of the product IMAGE RENEW 515 hydrothera...

Отзывы: