background image

3

WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the following
important precautions before using the RENEW 815.

READ AND FOLLOW ALL INSTRUCTIONS

1.

It is the responsibility of the owner to ensure
that all users of the RENEW 815 are ade-
quately informed of all precautions.

2.

Use the RENEW 815 only as described in this
manual.

3.

The RENEW 815 is intended for home use
only. Do not use the RENEW 815 in any com-
mercial, rental or institutional setting.

4.

Use the RENEW 815 only on a level surface.
Do not use the RENEW 815 on carpet or
other materials that could be damaged by
moisture. Do not use the RENEW 815 on
rough or sharp surfaces such as gravel or
wood chips.

5.

The RENEW 815 will weigh approximately
2,350 pounds when it is assembled and filled
with water. Be sure that the location you
select for the RENEW 815 will support this
weight, plus the weight of the occupants.

6.   Inspect and tighten all parts regularly.

Replace any worn parts immediately. 

7.

DANGERÑRisk of injury: Do not remove or
alter the covers on the suction fittings. Never
operate the RENEW 815 if the suction guard
is missing or broken. Keep hair and body
away from the suction guard. If you need to
replace a suction fitting, be sure that the flow
rate of the replacement is compatible.

8.

Do not bring any object into the RENEW 815
that could puncture the liner.

9.

Never insert any object into any opening.

10. Do not sit on the spa cover or place objects

on it. It is not designed to support weight. 

11. Remove any water that may collect on the

spa cover. 

12. Keep children and pets away from the

RENEW 815 when it is not in use. 

13. Keep all chemicals away from children and

pets.

14. The pH and chemical balance of the water

must be maintained as explained in this man-
ual (see page 13). Failure to do so may cause
injury to users or damage to the spa jet unit,
and will void the warranty.

15. The water pump in the spa jet unit must be

primed before you use the RENEW 815 the
first time. You must also prime the pump
before using the unit each time you re-fill the
spa or clean the filter. The spa jet unit may
be seriously damaged if the pump is not
properly primed (see PRIMING THE SPA JET
UNIT on page 10).

16. DANGERÑWhen connecting the power cord

(see PLUGGING IN THE RENEW 815 on page
10), plug the power cord directly into a
grounded circuit capable of carrying 15 or
more amps. No other appliance should be on
the same circuit. Replace the power cord
immediately if damaged.

17. Do not use an extension cord with the

RENEW 815. This could damage the motor
and the electrical system and it will void the
warranty.

18. DANGERÑIf you will be using the RENEW

815 outside, do not bury the power cord; you
should also keep the power cord away from
lawn mowers, hedge trimmers, and other
similar equipment.

19. WARNINGÑThe power cord is equipped with

a Ground Fault Circuit Interrupter (GFCI),
located at the end of the power cord. The
GFCI must be tested before each use. To test
the GFCI, press the ÒtestÓ button while the
spa jet unit is running. The spa jet unit
should shut off. Press the ÒresetÓ button.
The spa jet unit should resume normal oper-

Important Safety Instructions

Содержание 815inflatable

Страница 1: ...EE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST Model No IMHS81...

Страница 2: ...d in the center of this manual 2 Table of Contents The decals shown below have been placed on the RENEW 815 If a decal is missing or if it is not legible please call our Customer Service Department to...

Страница 3: ...gned to support weight 11 Remove any water that may collect on the spa cover 12 Keep children and pets away from the RENEW 815 when it is not in use 13 Keep all chemicals away from children and pets 1...

Страница 4: ...child could be seriously harmed 27 DANGER To reduce the risk of drowning Prolonged immersion in the RENEW 815 may cause hyperthermia a dangerous condition which occurs when the internal body temper a...

Страница 5: ...through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please note the product model number and serial number before calling The model number is IMHS81592 The serial...

Страница 6: ...r of the tub is 63 You should allow for this size plus the size of the spa jet unit plus room to remove the cover when choosing the location 8 Be sure to note any other considerations such as aestheti...

Страница 7: ...urround 9 Start the flap where the fastener strip starts and pull the flap tight as you go around Make sure the three holes in the Inflatable Liner are centered in the cutout in the Spa Surround 9 as...

Страница 8: ...Inflatable Liner 29 Slide a Wet Side Gasket 48 onto each connector Firmly tighten a Wet Side Nut 49 onto each con nector 4 Position the wet side jet pack B as shown Place an O ring 52 in the groove of...

Страница 9: ...important to smooth out as many wrinkles as possible Resume filling the spa until the water reaches the fill line Do not overfill the spa Note When the spa is filled the Spa Surround 9 may bow slightl...

Страница 10: ...with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the RENEW 815 First turn on the RENEW 815 by pressing the power button on...

Страница 11: ...60 to 64 F SECURING THE SPA COVER The spa cover can be secured by snapping the latch es on the spa cover into the buckles on the wood sur round The buckles can be locked by inserting the key and turni...

Страница 12: ...rained from the pump Replace the nut on the pump Replace the dry side shell filter cap and pillow 12 USING THE CONSOLE Refer to the console diagram at the right The function of each console control is...

Страница 13: ...5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep ch...

Страница 14: ...the water should heat Cover the RENEW 815 with the spa cover The spa cover must be tight The water will heat at a rate of 1 3 F an hour If you are using the spa indoors and the room tem perature is ma...

Страница 15: ...be kept outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use t...

Страница 16: ...ill take 1 to 3 days depending on the room temperature to heat the water in the spa The good news is that once the water is heated it will maintain its tempera ture for a relatively low cost You can r...

Страница 17: ...eater Pump Gasket 41 2 Wire Tie 42 5 Snap in Fastener 43 4 Filter Housing Screw 44 1 Index Washer 45 1 Surround Bottom 46 1 Temperature Probe Gasket 47 1 Temperature Probe Nut 48 2 Wet Side Nut 49 2 W...

Страница 18: ...1 33 36 20 36 35 5 5 15 5 5 5 8 28 2 26 18 18 38 38 19 10 25 29 9 13 6 42 42 42 42 43 10 14 21 24 12 40 43 44 41 42 27 27 17 7 51 50 51 50 3 30 45 48 49 49 48 32 46 47 36 36 34 52 EXPLODED DRAWING Mod...

Страница 19: ...sed by or attributable to the following incidents any dam age to the wood exterior resulting from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling da...

Отзывы: