TROUBLE-SHOOTING AND MAINTENANCE
Inspect and tighten all parts of the IMAGE
¨
7.0 stepper regularly. The stepper can be cleaned with a soft cloth
and mild, non-abrasive detergent. Keep liquids away from the console.
HOW TO ADJUST THE REED SWITCH
For the console to display correct feedback the pedals must move
at least 5 inches vertically with each step. If the console displays
incorrect feedback, the Reed Switch (61) should be adjusted.
First, refer to assembly step 2 on page 4 and remove the ten
indicated screws from the Side Shields (55, 62). Next, carefully
slide the Side Shields off the stepper.
Hold down the right pedal so that the Magnet (59) is even with the
Reed Switch (61). Refer to the inset drawing. Loosen the
indicated #8 x 1/2Ó Screw (25), slide the Reed Switch to the side
slightly, and retighten the Screw.
Make sure that the Magnet will
not hit the Reed Switch when the Pedal is moved.
Repeat until
the console displays correct feedback.
Carefully slide the Side Shields (55, 62) back onto the stepper and
reattach them with the ten #8 x 1/2Ó Screws (25). Install the four
bottom screws first.
8
61
61
25
59
62
55
59
Start the program.
Press the START/PAUSE button and begin
stepping. As you exercise, the stepping speed
will periodically change as shown by the profiles
on the left side of the console. Note: If the
stepping speed is too fast or too slow, it can be
adjusted with the REPS button. When the stepping
speed reaches the fastest setting, the MAX indi-
cator will light; when the stepping speed reaches
the slowest setting, the MIN indicator will light.
To pause the program before the program is
completed, press the START/PAUSE button. A
tone will sound, the console will pause, and the
TIME display will begin to flash. (Note: The
program will also automatically pause if the
pedals are not moved for five seconds.) To
restart the program, press the START/PAUSE
button or simply begin stepping.
The program will continue until no time remains in
the TIME display.
Follow your progress with the four displays.
During the program, the four displays will provide
continuous feedback (see page 6).
Turn off the power.
After the stepper pedals are not moved and the
console buttons are not pressed for ten minutes,
the power will turn off automatically.
THE INFORMATION MODE
The console features an
information mode that
keeps track of total
stepper usage. To select
the information mode,
first unplug the power
cord. Next, press the
START/PAUSE button
while another person
plugs in the power cord.
Continue pressing the
START/PAUSE button.
All displays and indicators on
the console will flash once. After a moment, the TIME
display will show the total number of hours that the
stepper has been used. The REPS/MIN display will
show the total number of repetitions completed,
divided by 100. If the display shows 66, for example,
6600 repetitions have been completed. (Note: If the
number exceeds 999, the overflow will be shown in the
CALORIES display.) To exit the information mode,
press the START/PAUSE button again.
3
4
5