Gas connection (Fig. 10)

The connection to a gas tank or gas line must be made 
by  a  qualified  person  in  conformity  to  current  updated 
UNI-CIG  7129  and  7131  standards  after  making 
sure  that  the  cook  top  is  prepared  for  the  type  of  gas 
available. If not, see: “Adapting to different types of gas”. 
Also check that the feed pressure falls within the values 
shown in the table: “User characteristics”. 

Fig. 10

Metal rigid/semi-rigid hook-ups

Make  the  hook-up  with  metal  fittings  and  pipes  (even 
flexible hoses) so as not to stress the components inside 
the cook top.
Note: - After installation, use soapy water to check the 
perfect seal of the entire connection system. 
Important  note:  make  the  connection  using  only  metal 
fittings and pipes (flexible, continuous-wall steel hoses 
or rigid copper or steel tubing) and in such a way that its 
entire length can be inspected.

Electrical connection (Fig. 11)

The  installer  must  be  qualified  and  is  responsible  for 
correct  electrical  connections  and  following  safety 
standards.
Prior  to  carrying  out  the  electrical  connection,  please 
ensure that:

s THEPLANTCHARACTERISTICSARESUCHASTOFOLLOWWHATIS

indicated on the matrix plate placed at the bottom of 
the working area;

s THATTHEPLANTISlTTEDWITHANEFlCIENTEARTHCONNECTION

following  the  standards  and  law  provisions  in  force.

The  earth  connectionis  compulsory  in  terms  of  the 
law.

Should there be no cable and/or plug on the equipment, 
use  suitable  absorption  material  for  the  working 
temperature  as  well,  as  indicated  on  the  matrix 
plate.  Under  no  circumstance  must  the  cable  reach  a 
temperature above 50°C of the ambient temperature.
If  connecting  directly  to  the  mains  power  supply,  fit  a 
multi-pole switch of a suitable size for the rated capacity 
with a clearance distance which completely disconnects 
the power line under overvoltage category III conditions, 
consistently  with  the  rules  of  installation  (the  yellow/
green  earth  wir  must  not  be  interrupted).  The  plug  or 
omnipolar switch must be easily reached on the installed 
equipment.

Fig. 11

Содержание ilfm series

Страница 1: ...INSTRUCTION MANUAL FOR GAS COOKTOPS ...

Страница 2: ...OPEN 24 7 ILVE ACCESSORIES ONLINE SHOP VY H PKL YHUNL VM JVɈLL THJOPULZ WVKZ HUK V OLY 03 HJJLZZVYPLZ H OL JSPJR VM H I VU ZOVW PS L JVT H ...

Страница 3: ... to indicate that burner A is currently selected for programming Use the P and P keys to select the timer of the burner to be programmed The selected burner is indicated by the flashing of its light The timer display shows 0 00 to indicate that the timer for the selected burner is not active To program the turn off time for the selected burner press the PT key again the timer display will show 0 0...

Страница 4: ...ock the keypad before unlocking the burners Unlocking the keypad To unlock the keypad press the KL key and the key of burner A for at least 2 seconds When the keypad is unlocked the decimal points in the level displays turn off Residual Heat When a burner goes out the relative display shows an H to indicate that the temperature of that burner is still high and the relative LED near the timer displ...

Страница 5: ... cm Setting burner A Setting burner B Setting burner C Setting burner D Timer setting Turning ON OFF Lock Time activation Setting burner A Setting burner B Setting burner C Setting burner D Timer setting Turning ON OFF Lock Time activation The lighting of an LED means that the function is active for that burner A flashing LED indicates that the timer of the relative burner has been activated The l...

Страница 6: ...must take place periodically bearing in mind the following s THE GLASS AND STEEL PARTS MUST BE CLEANED WITH suitable non abrasive or corrosive products found on the market Avoid chlorine base products bleach etc s AVOID LEAVING ACID OR ALKALINE SUBSTANCES ON THE working area vinegar salt lemonjuice etc s THE WALL BAFmE AND THE SMALL COVERS MOBILE PARTS OF the burner must be washed frequently with ...

Страница 7: ...fore installing the cook top install the gasket seal around the entire perimeter of the hole where it will be inserted The dimensions of the hole are shown in figures 6 7 8 9 For Filotop models the perimeter of the hole must be lowered by a depth of 1 5 mm The hole does not need to be milled for Semifilotop models The cook top can be installed on different materials such as brickwork steel marble ...

Страница 8: ...emifilotop models do not need to be lowered by 1 5 mm 1 AUXILIARY 2 SEMI RAPID 3 RAPID 74 770 510 R 11 771 1 0 511 1 0 490 1 0 750 1 0 1 5 R 12 1 3 2 4 2 1 AUXILIARY 2 SEMI RAPID 3 RAPID 4 TRIPLE CROWN Note Semifilotop models do not need to be lowered by 1 5 mm Fig 7 Mod 60 cm Mod 77 cm ...

Страница 9: ...PID 3 RAPID 4 TRIPLE CROWN Note Semifilotop models do not need to be lowered by 1 5 mm Fig 8 1120 R 11 1121 1 0 385 1 0 365 1 0 1100 1 0 1 5 R 12 74 384 1 3 4 2 1 AUXILIARY 2 SEMI RAPID 3 RAPID 4 TRIPLE CROWN Note Semifilotop models do not need to be lowered by 1 5 mm Fig 9 Mod 90 cm Mod 112 cm ...

Страница 10: ...ed and is responsible for correct electrical connections and following safety standards Prior to carrying out the electrical connection please ensure that s THE PLANT CHARACTERISTICS ARE SUCH AS TO FOLLOW WHAT IS indicated on the matrix plate placed at the bottom of the working area s THAT THE PLANT IS lTTED WITH AN EFlCIENT EARTH CONNECTION following the standards and law provisions in force The ...

Страница 11: ...m flow desired you must press the PT key MIN will remain displayed and no LEDs will flash so at this point you can press PT to exit the procedure or press the P or P keys to select another burner and set the minimum flow The minimum flow levels are then acquired and stored by the device and will be used during normal use of the cook top Selecting the type of fuel gas You can configure the cook top...

Страница 12: ...The burners have been unlocked 5 times in 15 minutes Wait 15 minutes before unlocking the burners Flt08 Power supply circuit anomaly Failure at the circuit Replace the device Flt09 Generic anomaly Power was cut to the device when another type of failure had occurred previously Unlock the burners Resonator anomaly Failure at the circuit Replace the device Flt0A All burners locked No gas Restore the...

Страница 13: ...mifast 101 1750 167 auxiliary 77 1000 95 wok 3 150 4000 381 Liquefied gas G30 G31 28 30 37 fast 87 3000 218 g h semifast 66 1750 127 auxiliary 50 1000 73 wok 3 102 4000 291 Natural gas G25 25 fast 132 3000 332 l h semifast 102 1750 194 auxiliary 80 1000 111 wok 3 160 4000 443 G20 10 fast 155 3000 286 l h semifast 117 1750 167 auxiliary 92 1000 95 wok 3 180 4000 381 ...

Страница 14: ...JVT H PUJS KPUN I UV SPTP LK V H KHTHNL OYV NO TPZ ZL PUJS KPUN MHPS YL V THPU HPU ZLY PJL VY ZL P O WYVWLY JHYL ULNSLJ HJJPKLU VY VYKPUHY LHY HUK LHY PUJS KPUN KL LYPVYH PVU VM WHY Z HUK HJJLZZVYPLZ HUK NSHZZ IYLHRHNL I ZL MVY W YWVZL MVY OPJO OL 03 WYVK J HZ UV ZVSK VY KLZPNULK J ZL VY PUZ HSSH PVU OPJO PZ UV PU HJJVYKHUJL P O HU ZWLJPÄLK PUZ Y J PVUZ MVY ZL VY PUZ HSSH PVU K ZL VY VWLYH PVU HM ...

Страница 15: ... SPTP LK H OL VW PVU VM 03 V P YLWSHJPUN VY YLWHPYPUN OL KLMLJ P L WHY VM OL 03 WYVK J PP WH PUN OL JVZ VM YLWSHJPUN VY YLWHPYPUN OL KLMLJ P L WHY VM OL 03 WYVK J PPP YLWSHJPUN OL 03 WYVK J VY P WH PUN OL JVZ VM YLWSHJPUN OL 03 WYVK J L 6 Y NVVKZ JVTL P O N HYHU LLZ OH JHUUV IL L_JS KLK UKLY OL Z YHSPHU VUZ TLY 3H V HYL LU P SLK V H YLWSHJLTLU VY YLM UK MVY H THQVY MHPS YL HUK MVY JVTWLUZH PVU MVY...

Страница 16: ...SLWOVUL 5 TILY 03 ZOV YVVTZ HYL VWLU KHPS MYVT HT WT HUK H YKH Z HT WT I HWWVPU TLU VUS VU H YKH Z PS L JVT H 5 LHK 6ɉJL 4VVYL YLL 3LPJOOHYK 0 VVYHR 9VHK HTILY LSS 83 H LUKPZO 9VHK VVYWHYVV 5 UP V L YLL 6ZIVYUL 7HYR 5L ALHSHUK 76 V_ VJRI YU OYPZ JO YJO ...

Отзывы: