background image

11

HANGING INSTRUCTIONS

Method 1

: Fixed mounting installation

Measure the holes for mounting and mount the product on a solid surface. Use a 6mm (15\64”) 

drill bit to drill two holes on the wall; then put the screw expansion tube(M4) into installation holes. 

Next, screw the two screws (M4*20) with a screwdriver. Screws need to be away from the wall about 
16-18mm. Slide the controller down over the two screws. Use the orange X’s on this page as a 
convenient drill template.

Method 2

: wall-mounted installation

Ensure all wires are secure. Install a nail / screw and then insert the mounting hook of the controller 
over the nail / screw.

10

1-877-540-5588       

iluminarlighting.com                    

[email protected]

© Copyright 2021, ILUMINAR Lighting

Subject to change without notice.

Use these sensor to monitor the temperature in a set environment. With a temperature shutoff, the 
controller will automatically dim or shut down the lights if the climate room temperature becomes 
too high.
- Keep the sensor out of direct light so the measured temperature is accurate.
- Insert the temperature sensor for group 1 into T1 or group 2 into T2.
- The temperature measured by the sensor will be displayed on the LCD.
- Place the temperature sensor as close as possible to the sensor of the existing climate control 
system, so both sensors will measure the same temperature (A).

- Keep the sensor out of direct light in order to avoid disrupting the temperature measurement; if 

necessary, please use a hood (B).
- Insert the plug of the temperature sensor into the T1 or T2 port (C).

Climate

Control 

System

Temp sensor 

shielded from

light

CONNECTING THE TEMPERATURE SENSOR

Содержание Touch+

Страница 1: ...USER MANUAL 877 540 5588 iluminarlighting com sales iluminarlighting com ILUM CTRL TC...

Страница 2: ...Control 2 Independant Rooms Sunrise Sunset Effects Battery Backup to Save Data Dual Temperature Zone input for High Heat Dimming Dual Temperature Probe Inputs Touch Screen Technology Pre Install Infor...

Страница 3: ...he necessary parts to begin HARDWARE AND ACCESSORIES Plug the RJ9 end of one of the controller cables into one of the RJ9 ports of the controller RJ9 RJ14 Plug the RJ14 end of the same controller cabl...

Страница 4: ...se a finger or stylus to change parameters but be careful not to damage display Control Mode Page Allows for your selection on HID or LED mode Monitoring Only for monitoring Parameters cannot be set A...

Страница 5: ...nd turn back to the Monitoring interface I Save Save the set parameters and turn back to the Monitoring interface Setting If in setting mode and there is no screen use for 60 seconds the display will...

Страница 6: ...UMINAR Lighting Subject to change without notice Use these sensor to monitor the temperature in a set environment With a temperature shutoff the controller will automatically dim or shut down the ligh...

Страница 7: ...and after 10 15 minutes the controller should turn all the lights back on MAINTENANCE DISPOSAL 1 Please do not open the controller because there is no serviceable parts in it If you open the controll...

Отзывы: