5
1-877-540-5588
iluminarlighting.com
•
Turn the dimming dial to cycle through the dimming levels.
•
If your lamp fails to start immediately, DO NOT cycle the power on
and off. This can damage the lamp and ballast.
•
If after 30 minutes your lamp is still not lit, shut off power to the
ballast, and reconnect.
•
This will begin the startup sequence again.
•
Until the lamp has achieved at least 100 hours of operation, the lamp
should never be turned off prior to running at least 15 minutes. In
case this happens, WAIT 1 hour before igniting the lamp again.
IT IS VERY IMPORTANT
that the lamp is given adequate time to cool
down before it is reignited. Allow a hot lamp to cool for 1 hour before
you try to restrike it. Hot re-strikes cause permanent lamp failure and
lumen output degradations. The lamp should never be turned off before
the lamp reaches full intensity, this may shorten its lifespan.
DO NOT
install fixtures in areas of high heat, such as an attic, tent or
closed closet. Mount units at least 24-60 inches apart.
1. End of Lamp Life (EOL) Protection
2. Short Circuit Protection
3. Open Circuit Protection
4. Ignition Failure Protection
5. Thermal Protection
6. Suitable for ILUMINAR Lighting Touch+ Controller
7. Suitable for HASH Controller / 0-10V Control
8. Total Control Range 50-115%
DIMMING
CASE LENGTH
249mm
9.80”
CASE WIDTH
249mm
9.80”
HEIGHT
609mm
23.98”
WEIGHT
6.2kg
13.66 lbs
PHYSICAL
SPECIFICATIONS
1. Max. allowable case temperature: 35º C / 95º F
2. Operation Temp: 0 - 35°C / 32-95°F.
3. Max. Humidity: 95%
4. Ignition Voltage: 5kV
CARE
HOT RESTRIKE
MOUNTING
LOCATION
BALLAST
PROTECTIONS
COMPATIBILITY
Compatible with all ILUMINAR Lighting MH DE lamps & HPS DE lamps as
well as the ILUMINAR Lighting Touch+ & HASH Environment controllers.