PLEASE READ CAREFULLY BEFORE INSTALLATION

INSTALLATION 

PROCEDURE

When possible, have a licensed electrician or electrical expert install all 
fixtures or aid in the electrical layout plans and/or diagrams prior to 
installation.

Check the electrical panel to ensure proper voltage is available for the 
number of fixtures installed. Panels should only support a total amperage 
of 80% of its capacity. ie 100 amp panel should never exceed 80 amps. 
For proper lamp break-in, we recommend that you run the remote ballast 
and lamp at 100% power for at least 100 straight hours after initial 
startup. This will improve lamp life and performance.

1.  Find a suitable location for the ballast with sufficient cooling and 

away from any heat source.

2.  Install the lamp firmly into the lamp socket of the reflector and connect 

the lamp cord to the ballast.

3.  Remove the power cord from the box. 
4.  Plug the power cord into the power source (electrical outlet).
5.  Once the lamp has fired, set your desired dimming ratio. Please note 

that the ballast dims or raises output gradually to protect the lamp, 
so you might not see an instant increase upon changing your output 
percentage.

• 

Turn the dimming dial to cycle through the dimming levels. 

• 

If your lamp fails to start immediately, DO NOT cycle the power on 
and off. This can damage the lamp and ballast. 

• 

If after 30 minutes your lamp is still not lit, shut off power to the 
ballast, and reconnect. 

• 

This will begin the startup sequence again.

• 

Until the lamp has achieved at least 100 hours of operation, the lamp 
should never be turned off prior to running at least 15 minutes. In 
case this happens, WAIT 1 hour before igniting the lamp again.

IT IS VERY IMPORTANT

 that the lamp is given adequate time to cool 

down before it is reignited. Allow a hot lamp to cool for 1 hour before 
you try to restrike it. Hot re-strikes cause permanent lamp failure and 
lumen output degradations. The lamp should never be turned off before 
the lamp reaches full intensity, this may shorten its lifespan.

DO NOT 

install ballasts in areas of high heat, such as an attic, tent or 

closed closet. Mount units at least 24-60 inches apart.

DIMMING

HOT RESTRIKE

MOUNTING

LOCATION

216mm / 8.50”

278mm / 10.94” 

150mm 

5.90”

1000W

DE REMOTE BALLAST

ILUMINAR presents the Remote DE ballast. Giving the grower 
more GPW than traditional lighting. Available in 750W and 
1000W versions gives the grower even more options to 
customize their room to whatever specs are required.

Rated Mains Voltage
Voltage Range (+/-10%)
Mains Frequency
Operational Frequency
Dimming Type
Ambient Temperature
Max. Temperature
Relative Humidity
Max. Humidity
Plug Type
Remote Mounting
Ignition Voltage

208-277V
187-290V

50/60Hz

140-220Hz

Gear / 945 / 1000 / EXT

-20...+40°C/-4...+104°F

75°C/167°F

85%
95%

Male NEMA L7-15 Twist Lock

5m/16ft

5kV

OUTPUT SPECIFICATIONS

End of Lamp Life (EOL) Protection
Short Circuit Protection
Open Circuit Protection
Ignition Failure Protection
Thermal Protection

PROTECTIONS

Case Length
Case Width
Height
Weight

PHYSICAL SPECIFICATIONS

278mm
216mm
150mm

4.2kg

10.94"

8.50"
5.90"

9.26lb

Input Volts
Input Current
Input Power
Min Power Factor
THD
Crest Factor
BTU
Inrush Current

240V

4.60A

1045W

0.95

<15%

<1.7

200

≤ 37.5 Amps

INPUT SPECIFICATIONS

208V

5.10A

277V

3.85A

CMH

VOLTAGE: 

208V

277V

240V

SKU: 

IL-RMCDE1K-277