PLEASE READ CAREFULLY BEFORE INSTALLATION

INSTALLATION 

PROCEDURE

When possible, have a licensed electrician or electrical expert install all 
fixtures or aid in the electrical layout plans and/or diagrams prior to 
installation.

Check the electrical panel to ensure proper voltage is available for the 
number of fixtures installed. Panels should only support a total voltage of 
80 of its capacity. ie 100 amp panel should never exceed 80 amps. For 
proper lamp break-in, we recommend that you run the remote ballast 
and lamp at 100% power for at least 100 straight hours after initial 
startup. This will improve lamp life and performance.

1.  Find a suitable location for the ballast with sufficient cooling and 

away from any heat source.

2.  Install the lamp firmly into the lamp socket of the reflector and connect 

the lamp cord to the ballast.

3.  Remove the power cord from the box. 
4.  Plug the power cord into the power source (electrical outlet).
5.  Once the lamp has fired, set your desired dimming ratio. Please note 

that the ballast dims or raises output gradually to protect the lamp, 
so you might not see an instant increase upon changing your output 
percentage.

• 

Turn the dimming dial to cycle through the dimming levels. 

• 

If your lamp fails to start immediately, DO NOT cycle the power on 
and off. This can damage the lamp and ballast. 

• 

If after 30 minutes your lamp is still not lit, shut off power to the 
ballast, and reconnect. 

• 

This will begin the startup sequence again.

• 

Until the lamp has achieved at least 100 hours of operation, the lamp 
should never be turned off prior to running at least 15 minutes. In 
case this happens, WAIT 1 hour before igniting the lamp again.

IT IS VERY IMPORTANT

 that the lamp is given adequate time to cool 

down before it is reignited. Allow a hot lamp to cool for 1hour before you 
try to restrike it. Hot re-strikes cause permanent lamp failure and lumen 
output degradations. The lamp should never be turned off before the 
lamp reaches full intensity, this may shorten its lifespan.

DO NOT 

install ballasts in areas of high heat, such as an attic, tent or 

closed closet. Mount units at least 24-60 inches apart.

1. End of Lamp Life (EOL) Protection
2. Short Circuit Protection
3. Open Circuit Protection
4. Ignition Failure Protection
5. Thermal Protection
6. Suitable for ILUMINAR Touch Controller & HASH Controller

PERFORMANCE 

REQUREMENTS

DIMMING

CASE LENGTH

275mm

10.87”

CASE WIDTH

178mm

7.01”

HEIGHT

113mm

4.45”

WEIGHT

3.5kg

7.71 lbs

PHYSICAL 

SPECIFICATIONS

1. Max. allowable case temperature: 35º C / 95º F
2. Ambient Temperature: 0 - 35°C / 32-95°F 
3. Max. Humidity: 95%
4. Ignition Voltage: 5kV

BALLAST CARE

HOT RESTRIKE

MOUNTING

LOCATION

BALLAST

PROTECTIONS

4

1-877-540-5588       

iluminarlighting.com                    

[email protected]

5

RATED VOLTAGE

120V-240V

277V

VOLTAGE RANGE +/- 10%

108-264V

249-305V

OPERATIONAL FREQUENCY

100 - 120Hz

RJ14 Controller Connection
Wieland Female
Wieland Male
120V SKU CORD: IL-WLDCRD-120V
240V SKU CORD: IL-WLDCRD-240V
277V SKU CORD: IL-WLDCRD-277V