CHARGING A HOT OR COLD BATTERY PACK

The Red Flashing Indicator light on the charger indicates that the battery pack temperature is 

outside the charging range. Once the battery pack is within the acceptable range, normal charging 

will take place and the red light will be continuous. Hot or cold batteries may take longer to charge. 

POWER THE CHARGER WITH AN INVERTER OR GENERATOR

The charger will operate with most generators and inverters rated at 350 Watts or higher.

MAINTENANCE AND STORAGE

Store your charger in a cool, dry place. As a general practice, it is best to unplug battery chargers 

and remove batteries when not in use. No battery pack damage will occur, however, if the charger 

and battery pack are left plugged in.

REPAIRS

The charger has no serviceable parts.

MOUNTING TO THE WALL

Use the wall mount guides to mark the hanging points.

 

         To reduce the risk of injury, always unplug the charger and remove the battery from 

the charger before performing any maintenance. Never disassemble the battery or charger. 

Contact a MILWAUKEE service facility for ALL repairs. 

To reduce the risk of injury and damage, never immerse your battery or charger in liquid or allow a 

liquid to flow inside them.

CLEANING

Clean out dust and debris from charger vents and electrical contacts by blowing with compressed 

air. Use only mild soap and a damp cloth to clean the battery pack and charger, keeping away from 

all electrical contacts. Certain cleaning agents and solvents are harmful to plastics and other 

insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlo-

rinated cleaning solvents, ammonia and household detergents containing ammonia. Never use 

flammable or combustible solvents around batteries, charger, or tools. 

Содержание TaskMaster TB-12U1000-P

Страница 1: ...U1000 P Read and understand all of the instructions and safety information in this manual before operating or servicing this tool TASKMASTER TOOLS 4730 Madison Road Cincinnati OH 45227 www ilsco com P...

Страница 2: ...hank you for buying a TASKMASTER TOOL Our mission is to bring product innovation and exceptional customer service to the marketplace This tool line is reliable dependable and durable for our customer...

Страница 3: ...ILSCO tool owners will be offered options to solve any tool replacement parts or repair issues Call 513 533 6200 or 800 776 9775 Monday to Friday 8 00AM to 5 00PM Eastern Time ET MILWAUKEE Batteries L...

Страница 4: ...ection used for appropriate conditions will reduce personal injuries Do not overreach Keep proper footing and balance at all times This enables better control of the battery operated tool in unexpecte...

Страница 5: ...y be ejected from the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation...

Страница 6: ...6 TB 12U1000 P Die release buttons Label Carrying loop Release button yBattery pack Battery release buttons LED worklight Advance trigger IDENTIFICATION...

Страница 7: ...7 TB 12U1000 P KIT INCLUDES 1 Battery Powered Tool 2 Milwaukee Batteries 1 Milwaukee Charger 1 Shoulder Strap 1 Case 2 Die Cases...

Страница 8: ...voltage 18 V Battery capacity 5 0 Ah Type of battery Lithium ion Charging time 60 min approx Hydraulic oil Shell Tellus S2 V 15 Operating temperature range 4 to 122 F Dimensions 16 5 in x 13 2 in x 3...

Страница 9: ...is complete Fast flashing red Battery is too hot cold Charging will begin when battery reaches correct charging temperature Slow flashing red Battery charge is pending Charging will begin when the fi...

Страница 10: ...fully discharged battery pack with an internal temperature in the normal range will charge in about 30 to 185 minutes depending on the battery pack Heavily cycled batteries may take longer to charge...

Страница 11: ...parts MOUNTING TO THE WALL Use the wall mount guides to mark the hanging points To reduce the risk of injury always unplug the charger and remove the battery from the charger before performing any mai...

Страница 12: ...ckly for 2 3 seconds and the tool will not run Charge the battery pack NOTE Immediately after using the battery pack the Fuel Gauge may display a lower charge than it will if checked a few minutes lat...

Страница 13: ...labeling marking and documentation requirements for shipping Li Ion batteries is dependent upon whether the particular batteries are rated greater than or less than 100 Wh Generally Li Ion batteries...

Страница 14: ...ide buttons pull out the battery cartridge To replace the battery cartridge push the new cartridge firmly into place 2 After inserting a battery cartridge check that it is securely in place by pulling...

Страница 15: ...the die clicks into place 3 Place the connector between the dies 4 Press the advance trigger and advance the ram so that the connector is held between the dies and insert conductor into the terminal...

Страница 16: ...pe the crimping head jaws free of metal shavings Wipe down all steel parts with WD 40 Store the tool in a non humid environment The tool should provide many years of service when given the proper main...

Страница 17: ...Head 1 6 714050 Screw 1 7 710973 Seal Disc 1 8 712496 Unlocking Bolt 4 9 101595 Needle Roller 2 10 715222 Piston 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 8 8 9 18 Part Part Description Qty 11 7...

Страница 18: ...18 TB 12U1000 P 14 17 13 19 18 21 1 10 11 9 8 7 6 5 4 3 2 12 15 16 20 24 25 22 23 26 27 28 17 17 11 9 10 TOOL PARTS BREAKDOWN...

Страница 19: ...2 11 714303 Lever PD 2 12 714347 Housing Front 1 13 711867 Supporting Loop 1 14 760203 Lock Screw 1 Part Number Part Description Qty 15 760232 Seal Disc 1 16 714318 Sliding Cover 1 17 714155 PT Screw...

Страница 20: ...20 TB 12U1000 P Notes Notes...

Страница 21: ...21 TB 12U1000 P Notes...

Страница 22: ...22 TB 12U1000 P Notes...

Страница 23: ...23 TB 12U1000 P Notes...

Страница 24: ...Service Date 03 18 Version 2 TASKMASTER TOOLS 4730 Madison Rd Cincinnati OH 45227 Phone 800 776 9775 513 533 6200 www ilsco com...

Отзывы: