![iLoq D5S.(A).SB Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/iloq/d5s-a-sb-series/d5s-a-sb-series_mounting-and-care-instructions_2044236014.webp)
Page 14 of 16
C. Insert the round extension piece inside the housing extension part opposite the side with the
black sealing, so that the recess is placed next to the black O-ring. Please check if the O-ring
is not damaged otherwise use a new one (spare part kit available “A5.005”).
D.
Insert the extension piece. Fix the extension piece with the fixing screw by using a T10 Torx
tool.
E. Insert the lock unit with extension piece back to the backbone of the cylinder housing. Fix the
lock unit into the cylinder by 3 fixing screws. Tighten screws. Use tightening torque 0.55 …
0.65 Nm.
C.
E.
D.