6. Installing in a Dropped Ceiling 

 

In buildings with a suspended or dropped 

ceiling  grid,  the  panels  (IHP2424  and 

IHP4824) may be  placed in the ceiling’s 

grid. 

They  are  sized  to  fit  into  standard 

suspended ceiling apertures. These ceiling 

grids are available in a 24” square format 

for small rooms or in 48” x 24” size for 

larger spaces. 

The IHP2424 panel is exactly 23.75” x 

23.75” and  will fit into  the  grid  and  be 

supported by the main runner (T bar) and 

cross tee. The IHP4824 panel is exactly 

47.75”  x  23.75”  and  will  be  uniformly 

supported by the runner design of a typical 

dropped ceiling structure. See 

Figure 6a. 

 

 

 

Mounting the heating panel in a dropped 

ceiling is easy as can be seen from 

Figure 

6b 

on the right. 

During operation, it is possible that the 

heating  panels  curve  up  slightly.  To 

ensure  the  most  aesthetically  pleasing 

installation, standard accessory hold-down 

clips may be placed in the corners to keep 

the  panels  level  when  these  expand. 

Please contact your ILO North America 

representative  to  obtain  a  set  of  these 

hold-down clips, if required. 

To reduce heat losses in installations with 

a  large  open  space  above  the  ceiling 

panels,  fiberglass  (or  similar  non- 

conductive)  insulation  capable  of 

withstanding  temperatures  of  at  least 

200°F (or about 90°C) may be used to 

cover the back of the unit. 

 

 

Figure 6a – Close-up of T Bar Support 

 

 

 

Figure 6b – Placing in Ceiling Grid 

Содержание IHP2424

Страница 1: ...Road Unit 205 60644 Chicago Phone 1 312 508 8600 Website http www ilo international com Affordable and Controllable Far Infrared Heating User and Installation Manual v1 84 For North America ILO Heati...

Страница 2: ...oosing one of ILO North America s innovative and class leading IR heating products It is our intention that you experience many years of satisfaction This product has been designed and manufactured to...

Страница 3: ...ting panel with any clothing towels wet or dry rugs curtains etc These flammable items will impair the correct operation of the heating panel and might lead to overheating of the panel and fire See th...

Страница 4: ...ctly into a power outlet receptacle Never use with an extension cord 11 Do not use outdoors 12 This heater is not intended for use in bathrooms laundry rooms and similar indoor locations Never locate...

Страница 5: ...mumcurrentconsumed when first powered up This start up current decreases as the heater warms up This current will vary slightly depending on the line voltage These figures are given to help in choosin...

Страница 6: ...ically protected against solid objects greater than 2 5mm 0 10 causing harm to the heater but have no protection against water spray These heating panels are designed for indoor use in non wetted area...

Страница 7: ...bient Humidity This is the maximum relative humidity in the local environment for the heating panel These panels are not designed for use in wet or damp environments Their protection class rating is I...

Страница 8: ...arized grounding adapter plug must be used It is essential that the grounding lug on this adapter plug is screwed to the grounding point on the outlet As this type of adapter plug is illegal in some j...

Страница 9: ...y supported by the runner design of a typical dropped ceiling structure See Figure 6a Mounting the heating panel in a dropped ceiling is easy as can be seen from Figure 6b on the right During operatio...

Страница 10: ...ge 9 When wall mounting it is recommended to use these brackets Type A brackets are for the IHP2424 panel type B brackets are for the IHP4824 and type C brackets are for the IHP4141 panel Mounting Bra...

Страница 11: ...or security wire in wall and on ceiling installations Owing to the design of the safety latch mechanism the heaters can be removed from the mounting brackets without the need of tools The brackets ma...

Страница 12: ...or security wire in wall and on ceiling installations Owing to the design of the safety latch mechanism the heaters can be removed from the mounting brackets without the need of tools The brackets ma...

Страница 13: ...building and region Installation 1 Locate an area near an active power outlet or employ an electrician to provide a power outlet within 6 feet 2 0m of the heating panel 2 Install the two mounting brac...

Страница 14: ...and or chains may be secured through the appropriate size holes at the ends of the panel s mounting brackets Please contact your ILO North America representative for further advice on mounting panels...

Страница 15: ...maintainacomfortableheatingenvironment Note the heating panel is placed close to the typicalseatingareaformaximumbenefit Infrared Heating System Wall Mounted Alternative Set up Figure 9e Figure 9f Fig...

Страница 16: ...8 C lower when using an infrared heating system to achieve the same level of perceived heating comfort In place of the typical 70 F 21 C setting the thermostat can be set to 66 5 F 19 2 C Itis this l...

Страница 17: ...K DO NOT OPEN NO USER SERVICEABLE PARTS INSIDE As the ILO Heating Panels are maintenance free it is not required for a user to ever open the heater The heating panels are secured by rivets to prevent...

Страница 18: ...rect the problem Circuit breakers may trip if too many appliances are connected to the same circuit this is not considered an ILO product defect c If the outlet is OK and you have used an optional roo...

Страница 19: ...violet wavelengths The sun s rays travel a great distance through space without requiring a medium to transmit its energy ILO s far infrared FIR radiant heating technology operates in the healthy and...

Страница 20: ...eople perceive radiant heating as being more comfortable than convection heating systems According to DIN EN ISO 7730 most people 90 react more favorably to Far IR heating than convection heating The...

Отзывы: