LED-in_plastica_IM_ITA-ENG-Rev.12 of 19/07/18
Pag.8 of 8
Made in Italy
ISTRUZIONI DI MONTAGGIO E
MANUTENZIONE
MOUNTING AND MAINTENANCE
INSTRUCTION
LED-in luminaire is classified
under “
EXEMPT GROUP
”
according to photobiologycal
safety standard
IEC/EN 62471
.
NO RISK
for the operators and end users.
n°LED
WEIGHT [kg]
Projection subject to the wind
18 LED
9.5
Base area
0.217 m
2
27 LED
10
36 LED
10
Side area:
0.076 m
2
45 LED
10
54 LED
10
Form factor: 1.2
63 LED
10.5
72 LED
10.5
Max height of installation: 15m
81 LED
11
90 LED
11
F
Fuse 250Vac 10A (suggested size)
PD
Protection device
CN
Connector
PSU
LED Power Supply
F1 (optional)
L
N
LED
modules
CN2
PSU
ELECTRICAL SCHEME
CN1
PD
Protection earth
(only class I)
External
connector
In order to insure double
insulation characteristic of the
feeder cable, we would advise
that you first secure the feeder
cable to the internal cable
clamp, remove approximately
20mm of external sheathing,
and 6-7mm of sheathing from
the internal wires.
ELECTRICAL LINE CONNECTION
< 2 0 mm
6
7 mm
This symbol on the product or in its packaging is based on WEEE
Directive (Directive on Waste Electrical and Electronic Equipment),
which is a regulation in EU member countries, and this symbol
indicates that this product shall not be treated as household waste.
To reduce the environmental impact and minimize the volume of
landfills, please cooperate in reuse and recycle.
For how to dispose of the product, please contact your dealer or the
nearest AEC Illuminazione sales office.
INFORMATION TO THE CUSTOMERS
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European
countries with separate collection system)
Dimensions
ATTENTION
a)
b)
a)
Replace any cracked protective shield.
b)
During maintenance, do not stare at the operating light source.
c) Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical
components.
d) Use only devices with supplementary insulation between 1-10V/DALI terminals and mains terminals.
e) The device has developed in compliance with the current standards; it is necessary that the installation is done properly, according with the
instructions supplied.
f) The present instruction paper has to be kept for any future maintenance operation on the luminaire. Non-compliance with the above will
automatically release AEC Illuminazione Srl from any responsibility.