BEFORE YOU BEGIN

WARNING!

Installation, trouble shooting, and replacement of parts are to be performed

only by authorized service technicians.

Electrical Requirements:

• The motor amperage and voltage ratings must be checked for

compatibility to supply voltage prior to final electrical connection. Please

refer to the motor's nameplate label.

• Wiring must conform to local, state, and national codes.

Tools / Materials Needed:

• Mounting Fasteners (8)

• Sealant or Caulk

• Regular Screwdriver Set

Recommended Accessories:

• Speed control for ILG8SF7V, ILG8SF10V, ILG8SF12V, ILG8SF16V,

ILG8SF18V, ILG8SF20V, ILG8SF24V

U

UNPACKING

Contents:

• Shutter Mounted Exhaust Fan

• Owner’s Manual

Inspect:

• After unpacking fan, carefully inspect for any damage that may have

occurred during transit. Check for loose, missing, or damaged parts.

• Check all bolts, screws, set-screws, etc. for looseness that may have

occurred during transit. Tighten as needed. Rotate propeller by hand to

ensure it turns freely.

• See General Safety Instructions on page 3, and Cautions and Warnings

as shown.

Содержание ILG8SF10V

Страница 1: ...1 SHUTTER MOUNTED EXHAUST FAN Models ILG8SF7V ILG8SF10V ILG8SF12V ILG8SF16V ILG8SF18V ILG8SF18S ILG8SF20V ILG8SF24V ILG8SF30S ILG8SF36S OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...voltage prior to final electrical connection Please refer to the motor s nameplate label Wiring must conform to local state and national codes Tools Materials Needed Mounting Fasteners 8 Sealant or C...

Страница 3: ...he National Electrical Code NEC and the Occupational Safety and Health Act OSHA in the United States and the Canadian Electric Code CEC in Canada 8 Always disconnect power source before working on or...

Страница 4: ...ch as thermostats switches or speed controls 3 Connect power to the motor using an approved wiring method Refer to the following wiring diagrams Figure 1 Figure 2 Fan frame and motor must be securely...

Страница 5: ...5 Figure 2 Wiring Diagram Single speed 115 volt connection for ILG8SF18S ILG8SF30S ILG8SF36S...

Страница 6: ...2 ILG8SF12V 12 15 15 5 3 4 2 6 5 32 13 5 8 12 1 8 12 1 8 8 3 1 2 9 32 1 2 13 ILG8SF16V 16 18 29 32 18 29 32 5 3 4 2 7 7 8 17 3 4 16 16 11 29 32 3 17 32 9 32 1 2 17 ILG8SF18V 18 21 21 5 3 4 2 8 3 4 19...

Страница 7: ...4 2 75 1075 Ball 6 67 3368 2312 1868 ILG8SF24V 24 1 4 2 75 1075 Ball 7 4244 2676 2220 ILG8SF30S 30 1 3 3 30 825 Ball 7 01 5088 3432 1552 ILG8SF36S 36 1 2 6 00 825 Ball 8 24 6128 4380 2620 1 Keep the a...

Страница 8: ...tor bearings as per instructions or replace motor Loose propeller Tighten set screws on propeller hub Bent or damaged propeller Replace propeller Loose guard assembly or motor fasteners Tighten as req...