background image

9

F

X

R

U

A

B

C

A 1 )   B u r n e r s   o f   t h e   h o b

1.  Remove the grill, the caps and the burners from the worktop.
2.  Lift the worktop.
3.  Unscrew the screw “F” and remove the pipe “R”.
4.  Save the orifi ces removed from the appliance for future use.
5.  Unscrew the injectors (U) and replace them with those suitable for the gas used, supplied with the cooker. See 

TABLE 2

.

6.  The air is adjusted by means of the pipe “R” according to the value “X” given in 

TA B L E   2

 for the primary air opening. 

Once regulation has been completed, secure the pipe ”R” with the screw “F”.

A 2 )   A i r   a d j u s t m e n t

The air adjustment must be carried out with the burner ignited and the flame to the maximum.
Examples (

F i g . 4

):

A)  Flame with excess of air; it is small and thin. Move sleeve R forward.
B)  Flame with lack of air; it is irregular with yellow streaks. Move sleeve R backward.
C) Normal fl ame: its colour is light blue.

 

F i g u r e   3  

F i g u r e   4

  F i g u r e   6   ( D U A L )

F i g u r e   5

ADJUSTING THE MINIMUM GAS FLOW

When installing the gas cooktop you must check that the minimum gas fl ow of the burners is correctly regulated. If the 
type of gas is changed it is indispensable to adjust the minimum fl ow. The regulating procedure is as follows.

A) Burners on the hob (fig. 5)

1.  Light one burner at a time and turn the flame up to maximum.
2.  Remove the knob of the corresponding gas tap and insert screwdriver in the screw as showed in figure 6 

(DUAL).

3.  Turn the tap to minimum position.
4.  Unscrew, turning to the left, to increase the flame, or screw to the right to decrease it.
5.  If a liquid gas is used (Butane - Propane), the regulating screw must be fully screwed in.

AU X

Содержание DUHP765N

Страница 1: ...HP1265 FD FDN UHP765 UHP765N UHP765 D DN WARNING If the information in this manual is not followed exactly a fine or explosion may result causing property damage personal injury or death Do not store...

Страница 2: ...turer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance The manufactured reserves the right to make changes to its prod...

Страница 3: ...onents may be hot enough to cause burns Never leave this appliance unattended when in use Boilovers and greasy spills may smoke or ignite Do not heat unopened food containers such as baby food jars an...

Страница 4: ...Pa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to...

Страница 5: ...T handle type manual gas valve must be installed in the gas supply line to this appliance Refer to the illustration 2 Pressure Regulator 1 All heavy duty commercial type cooking equipment must have a...

Страница 6: ...iction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualifi...

Страница 7: ...fice must be fully screwed in To convert the regulator Fig 1 and Fig 2 for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by...

Страница 8: ...TURAL A 10500 145 2700 Open Adj TC NATURAL A 15500 180 4000 Open Adj Dual NATURAL A 15500 165 68 6300 15 external Open inner ring Adj Dual aux only NATURAL A 2300 68 800 Open Adj Griddle NATURAL A 105...

Страница 9: ...t is small and thin Move sleeve R forward B Flame with lack of air it is irregular with yellow streaks Move sleeve R backward C Normal flame its colour is light blue Figure 3 Figure 4 Figure 6 DUAL Fi...

Страница 10: ...ust not be used for heating purposes IMPORTANT correct positioning of the brass flame distributor d Fig 7 is very important For this purpose ensure that the flame distributor tooth e Fig 7 coincides w...

Страница 11: ...to reignite the burner turn the knob in a clockwise direction past the limit stop until you reach the required level SURFACE BURNERS Before lighting place the burner head and cap on each burner base...

Страница 12: ...l cooking is available as an optional accessory Some models are supplied with the spatula shown in Figure 9 which is useful both for cooking and for cleaning the plate CLEANING AND CARING FOR THE FRY...

Страница 13: ...pending on the quantity and temperature of the food the type of gas and of course your own personal taste COOKING TABLE purely indicative values after 10 preheating with the burner at maximum power Kn...

Страница 14: ...illustration below Reinsert the cooktop into the countertop opening Lift the entire cooktop to make adjustments Attach the brackets to the bottom of the unit Insert the clamping screws into the bracke...

Страница 15: ...natural and LP gas If a flexible metal connector is used be sure the tubing is not kinked Open the shut off valve in the gas supply line Wait a few minutes for the gas to move through the line GAS LE...

Страница 16: ...to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high...

Страница 17: ...17...

Страница 18: ...P765 UH965 UHP1265 A hole of 1 31 32 5 cm x 5 cm must be done on the top for power cable and gas conduit as shown in picture The supplied feet h 0 5 16 0 8 cm must be fitted in the special holes under...

Страница 19: ...13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Within the 16 40 64 cm side clearance to combustible vertical surfaces above...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...HP65 C CN D DN UHP75 C CN D DN UHP95 PC PCN PD PDN FC FCN FD FDN C CN D DN UHP1230 D DN UHP125 PC PCN PD PDN FC FCN FD FDN UHF40 UHF40N UHF40 F FN D DN UHP665 UHP665D UHP965 UHP965 F FD PD 6 6D UHP126...

Страница 23: ...3 UXLP90F UXLP90FD LEGEND M Terminal board MA Electrical ignition microswitch EL Valve DS1 Electronic controller 00 Black 22 Red 33 White 45 Green 66 Blue K1 Earth wire terminal board N Neutral L Phas...

Страница 24: ...24 ELECTRICAL AND GAS POWER TABLE...

Страница 25: ...25 NOTES...

Страница 26: ...26 NOTES...

Страница 27: ...27 NOTES...

Страница 28: ...COOKERS OVENS HOB COOKERS INDUSTRIA LAVORAZIONE VENETA ELETTRODOMESTICI S p A Via Antoniana 100 35011 Campodarsego PD Italy Tel 39 049 9200990 Fax 39 049 9201010 mail ilve com www ilve com...

Отзывы: