Doc ID: TN-052 HMT-402 & Series Basic Setup V1.doc 

Page:       2 of 2 

Prepared by:  DN 

Date:  17-Dec-2013 

Approved by: TN 

Date: 17-Dec-13 

Modulator Settings for A &B channel where appropriate 

Note:  

RF output bandwidth separation not less than set bandwidth or more than 32MHz. 
E.g. Channel A: 599.500 & Channel B: 606.500 MHz 

  Set the output frequency (centre digital frequency, not analogue carrier). 

  Set the RF output frequency (MHz) to designed digital channel

  Set the Bandwidth to 

7MHz

.

  Set the Guard Interval to 

1/16 

  Set the Constellation to 

64QAM 

  Hierarchy information to 

Not Hierarchy

  Set the Code Rate to 

3/4

  Transmission Mode to 

8K 

Edit NIT table Settings 

  Visible box should be ticked for all Service ID and LCN settings 

  Service ID 0x111 LCN e.g. 501 (Set the LCN (Logical Channel Number) for inputs 1 to 4,

 to avoid conflict 

with Free-To-Air channels, start the LCN numbers at 500 (unallocated numbers) and do not go any 
higher than 549

.) 

  Service ID 0x112 LCN e.g. 502 (Set the LCN (Logical Channel Number) for inputs 1 to 4 t

o avoid conflict 

with Free-To-Air channels, start the LCN numbers at 500 (unallocated numbers) and do not go any 
higher than 549

.) 

  Service ID 0x121 LCN e.g. 503 (Set the LCN (Logical Channel Number) for inputs 1 to 4,

 to avoid conflict 

with Free-To-Air channels, start the LCN numbers at 500 (unallocated numbers) and do not go any 
higher than 549

.) 

  Service ID 0x122 LCN e.g. 504 (Set the LCN (Logical Channel Number) for inputs 1 to 4,

 to avoid conflict 

with Free-To-Air channels, start the LCN numbers at 500 (unallocated numbers) and do not go any 
higher than 549

.) 

The service ID (SID)  and LCN must be changed if combining or cascading HMT products  

  For second unit SID and LCN would be 

  0x211 LCN 505 0x212 LCN 506, 0x221 LCN 507, 0x222 LCN 508  

  Ikusi has picked these SID to make it easer to recognised which unit is which 0x 111 first character 

represents HMT unit 1 second character the input module in unit, 3

rd

 character represents the HDMI 

stream 

SID needs to be changed in the Input1 & Input 2 screens. 

SID and LCN also need to be changed in NIT (A & B) table by selecting detail and editing and saving 
changes  

Firmware updates  

  When updating firmware do not try to restore configuration from a previous firmware version as this may 

corrupt settings. 

  After upgrading firmware you will need to reboot HMT via the browser, do not switch on and off. 

  Save configuration via the browser. 

  In restore / save menu load factory reset via browser. 

  After steps above manually adjust input setting modulation setting and NIT table setting. 

  Save configuration check unit operates OK, and then power cycle unit (not reboot) and check again if OK 

make backup configuration file if required 

Final points 

  Check welcome page Status/Alarm are OK 

  TS overflow should be green for both A & B as appropriate to model being used 