Ikon IK82 Скачать руководство пользователя страница 2

-2-

INTRODUCTION OF DEVICE

3110

3120

3130

3131

3140-3141

3150-3151-3155

3160

3158

3170

250

26

2

4

6

426

50

0

M

in

6

3

5

M

ax

1

0

1

5

59

8,7

98

,89

8

500

2

0

4

0

0

2

0

8

0

6

0

0

4

0

500

59

8,7

98

,89

8

250

26

2

M

in

6

3

5

M

ax

1

0

1

5

2

0

4

0

0

6

0

0

2

0

8

0

500

59

8,8

98

250

26

2

M

in

6

7

5

M

ax

1

0

5

5

8

3

2

0

4

0

0

6

0

0

2

0

8

0

500

59

8,8

98

250

26

2

M

in

6

7

5

M

ax

1

0

5

5

8

3

2

0

4

0

0

6

0

0

2

0

8

0

8

0

500

59

8,8

98

250

26

2

M

in

6

7

5

M

ax

1

0

5

5

2

0

4

0

0

6

0

0

2

0

8

0

2

0

5

7

,6

6

46

0,6

00

59

8,8

98

410

500

M

in

(9

0

)

6

3

5

(6

0

)

6

3

0

M

in

(9

0

)

1

2

1

5

(6

0

)

1

2

1

0

6

0

0

4

0

0

2

0

8

0

250

26

2

2

5

8

0

4

0

0

5

0

0

2

0

500

598

,89

8

250

262

420

M

in

(9

0

)

6

0

0

(6

0

)

5

3

5

M

ax

(9

0

)

9

8

0

(6

0

)

9

1

5

412

6

2

,1

2

6

4

6

50

0

250

M

in

6

4

0

M

ax

1

0

2

0

60

0,7

00

,80

0,9

00

2

0

4

0

0

6

0

0

2

0

8

0

26

2

426

500

6

0

500

60

0,7

00

,80

0,9

00

250

26

2

M

in

6

5

5

M

ax

1

0

3

5

2

0

8

0

6

0

0

4

0

0

2

0

3110

3120

3130

3131

3140-3141

3150-3151-3155

3160

3158

3170

1

)

 

Internal Chimney

2) External Chimney
3) Control Panel
4

) Cooker Lighting

5) Aluminum Cassette Filter

6) Tempered Glass

1

2

3

4

5

6

1

2
3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

6

1

2

3

4

5

6

1
2

3

4

5

6

1

2

3

4

5

FUSE

ELECTRONIC  CIRCUIT

CAPASITOR

5
µ

f

/4

0

0

V

M

FUSE

800m³/h 5 Speed

FUSE

5µF

1

0

1

0

10

M

CAP

C

A

P

N

M

1

M

2

M

3

M

4

M

5

LAMP

500 m³/h 3 Speed

FUSE

C

O

N

T

R

O

L

P

A

N

E

L

ELECTRONIC  CIRCUIT

M

5µF

BROWN

YELLOW/GREEN

BLUE

M

CAP

C

A

P

N

M

1

M

2

M

3

M

4

M

5

B

U

T

T

O

N

B

O

X

INPUT : 220 - 240 V AC  / 50 Hz

ELECTRONIC  CIRCUIT

M

WHITE

WHITE

LAMP

BLACK

BLUE

RED

WHITE

BROWN

YELLOW/GREEN

BLUE

800 m³/h 3 Speed

C

O

N

T

R

O

L

P

A

N

E

L

LAMP

WHITE

WHITE

BLACK

WHITE

BLUE

RED

BROWN

BROWN

YELLOW/GREEN

BLUE

INPUT : 220 - 240 V AC  / 50 Hz

INPUT : 220 - 240 V AC  / 50 Hz

C

O

N

T

R

O

L

P

A

N

E

L

CAPASITOR

800 m³/h 3 Speed -12V

WHITE

BLACK

BLUE

RED

BROWN

TRANSFORMER

220 V

12 V

WHITE

WHITE

LAMP

12 V

BROWN

YELLOW/GREEN

BLUE

LAMP

BLACK

GREY

YELLOW

WHITE

BLUE

BROWN

RED

GREY

GREY

BROWN
YELLOW/GREEN

BLUE

WHITE

WHITE

WHITE

WHITE

ELECTRONIC  CIRCUIT

BUTT

ON BOX

INPUT : 220 - 240 V AC  / 50 Hz

LAMP

WHITE

WHITE

WHITE

WHITE

BLACK

GREY

YELLOW

WHITE

BLUE

BROWN

RED

GREY

ELECTRONIC  CIRCUIT

800m³/h 5 Speed LCD

Содержание IK82

Страница 1: ...TAPWARE RANGEHOODS COOKTOPS WASTE DISPOSALS KITCHEN LAUNDRY SINKS BATHROOM BASINS Rangehood Installation and User Manual Model IK82 ...

Страница 2: ...5 Aluminum Cassette Filter 6 Tempered Glass 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 FUSE ELECTRONIC CIRCUIT CAPASITOR 5 µ f 400 V M FUSE 800m h 5 Speed FUSE 5µF 10 10 10 M CAP CAP N M1 M2 M3 M4 M5 LAMP 500 m h 3 Speed FUSE CONTROL PANEL ELECTRONIC CIRCUIT M 5µF BROWN YELLOW GREEN BLUE M CAP CAP N M1 M2 M3 M4 M5 BUTTON BOX INPUT 220 240 V AC...

Страница 3: ...cket before installation of the product is completed Keep the plug at a reachable place so that you can unplug it in case of any danger Do not touch the lamps when they are on for long time Lamps may hurt your hand as they will be hot Kitchen cooker hoods are designed for usage during normal and home style cooking If it is used for other purposes failure risk occurs and it will be out of warranty ...

Страница 4: ...t for your security CAUTION Accessible parts may become hot when used with cooking appliances The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 17 MAINTENANCE Disconnect electricity connection before maintenance and cleaning process Aluminum cassette ...

Страница 5: ...panel are used for turning the device on The models with eletronic controllers have automatic timers 15 minutes automatic timer is turned on when pressed any of the buttons which starts the motor up more than 2 seconds When timer starts display will signal and after 15 minutes motor will automaticly stop Please turn on hob and hood at the same time to activate circulation This will provide positiv...

Страница 6: ... When button is pushed for approximately 5 seconds blue color percentage appears on the screen for example b 00 When V button is pushed once more red color percentage will appear on the screen for example r100 When V button is pushed once more green color percentage will appear on the screen for example g10 Pressing Tmr and Tmr buttons pressing for longer time it can be set fast the color whose pe...

Страница 7: ... for stopping the cooker hood If the timer is set when the motor is operating cooker hood will stop lamp will be off and buzzer will ring for 5 seconds when timer period is over 2 Timer for alarm If the timer is set when the motor is not operating alarm timer will have been started When the timer is over buzzer will ring for 15 seconds even though motor is operated or the lamps are set to on posit...

Страница 8: ...est of smell and steam Cleaning Periods of theAluminum Filters Filters should be cleaned when C signal appears on Display or according to usage each 2 3 weeks In order to remove C signal after the filters are cleaned and replaced to their place press button more than 3 seconds when the product is at off position Letter E will appear on Display and the product will operate as normal If you would li...

Страница 9: ...ou want to continue using your product without removing C signal active speed will appear for 1 second when you press button then C signal will appear once more and the motor will continue operating Illumination The product has 2 lamps and one lamp button to operate illumination Press lamp button in order to start illumination Installing the External Chimney Place internal chimney into external ch...

Страница 10: ...should not be connected to air canals that have other smoke as well Active Carbon Filter To provide air recirculation where product s chimney air outlet cannot be connected to exterior it is necessary to use active carbon filter with your product You may purchase this accessory from authorized sellers and after sales services 11 Carbon Filter Usage Your product is compatible with two types of carb...

Отзывы: