15/09/2018
26
13.
Insert the flue ingress plate on the motor box with the screws
that you have removed (Fig. 32).
14.
Mount the electronic circuit box inside the kitchen counter
with 4 3.9x22 screws with M4 nuts (Fig. 33).
15.
Place the metal container towards the arrow inside the appli-
ance (Fig. 34).
Fig. 32
1- Flue Connection Plate Fixing
Screws
2- Flue Connection Plate
3- Motor Box
Fig. 33
1- 3.9x22 Screw
2- M4 Washer
2- Electronic Circuit Box.
Fig. 34
1- Metal Container
ASSEMBLY OF PRODUCT
15.09.2018
FREE FLOW Hoods
27