Instructions for installation and use | IKI electric heater with separate control unit
Sivu 10
Mechanical
ventilation
The
ventilation
in
the
sauna
room
needs
to
be
considered.
Proper
air
‐
flow
allows
bathers
to
enjoy
fresh,
oxygen
‐
rich
air.
The
air
should
fully
change
6
times
an
hour.
The
supply
air
inlet
should
be
installed
on
the
wall
or
the
ceiling
at
about
500
mm
above
the
heater.
The
supply
air
inlet
vent
should
be
50
‐
100
mm
in
diameter.
The
outlet
vent
should
be
located
as
far
away
from
the
heater
as
possible,
close
to
the
floor.
The
outlet
vent
should
be
twice
the
size
of
the
inlet
vent.
NOTE!
The
sensor
for
the
thermostat
should
be
located
at
a
minimum
of
1000
mm
distance
from
undirected
vent
for
replacement
air,
or
minimum
of
500
mm
distance
from
the
air
vent
directed
away
from
the
sensor.