background image

P a g e

 | 

IKI Wood burning stoves | Instructions for installation and use 

IKI Wood burning stoves | Finnish high-quality craftsmanship 

2.

 

Installation of the stove 

2.1 Mini-IKI and Original IKI 

 

 

 

1.

 

Unpack the package and check that all parts 

belonging to the stove are included in the 

delivery. A: Stove B: Fire plate, gloves and 

instructions (inside the ash box) C: Carrying 

handle D: Chimney pipe E: Ash tool F: Glass hatch 

 

2.

 

Cut the cable tie with scissors or utility knife to 

unleash the carrying handle from the back of  

the stove. 

 

 

3.

 

Move the stove by carrying it from the carrying 

handle and from the top of the furnace. Remove 

the carrying handle after the stove is in place. 

4.

 

Set the stove on a solid and fireproof base in  

the middle of the installation place.  

Baseplate’s 

(A)

 purpose is to set the stove into  

a straight and horizontal position. You may only 

open and adjust each one of the "trim screws" 

(B)

 in the baseplate legs a maximum of 0,4 inches 

(10 mm). 

Содержание Mini-IKI

Страница 1: ...Instructions for installation and use IKI Wood burning stoves Mini IKI Mini IKI Plus Original IKI Original IKI Plus 1 2022 ...

Страница 2: ...will cause early rusting Beware of the blast connection hatch or other metal surfaces of the stove and the stones THEY MAY BE HOT Always wear protective gloves mittens etc With children take special precautions in the sauna In addition to this instruction the EU heater standard 15821 local fire rescue authorities rules and regulations must be taken into account when installing and using the stove ...

Страница 3: ...s to flammable structures 10 3 1 Reducing the safety distances 10 4 Dimensional drawings and Connection heights 11 5 Model table 12 6 Instructions for using the stove 13 6 1 Initial load and lighting the fire 13 7 Troubleshooting 14 8 The water quality for the stove 14 9 Sweeping instructions 15 10 Ventilation of the sauna and getting compensation air 16 10 1 Tips for ventilation 16 10 2 Automatic...

Страница 4: ...ling 100 mm 100 mm 1100 mm Emission of combustible products Passed Surface temperature Passed Release of dangerous substances NPD Cleanability Passed Flue gas temperature average 346 C Mechanical resistance Passed Sauna room heating output 16 6 kW carbon monoxide emission 13 O2 CO emission 13 O2 Passed 867 mg m cardon monoxide emission at 13 O2 CO emission 13 O2 Passed 0 069 total efficiency Passe...

Страница 5: ...iling 100 mm 100 mm 1100 mm Emission of combustible products Passed Surface temperature Passed Release of dangerous substances NPD Cleanability Passed Flue gas temperature average 411 7 C Mechanical resistance Passed Sauna room heating output 15 1 kW carbon monoxide emission 13 O2 CO emission 13 O2 Passed 1242 mg m cardon monoxide emission at 13 O2 CO emission 13 O2 Passed 0 10 total efficiency Pa...

Страница 6: ...f the stove is a Plus model the delivery also includes 1 pc upper mesh for the stove 1 pc straight chimney pipe Before installation make check the following Safety distances to inflammable surfaces and incombustible structures The connection height of a possible old chimney and installation route of a new chimney that will possibly be installed Floor material and weight capacity inflammable incomb...

Страница 7: ...D Chimney pipe E Ash tool F Glass hatch 2 Cut the cable tie with scissors or utility knife to unleash the carrying handle from the back of the stove 3 Move the stove by carrying it from the carrying handle and from the top of the furnace Remove the carrying handle after the stove is in place 4 Set the stove on a solid and fireproof base in the middle of the installation place Baseplate s A purpose...

Страница 8: ...re plate in the front of the furnace s slots Fire plate prevents the hot cinders from falling to the floor 6 Install the glass hatch to the hinge A by removing the hinge bolt B 7 Then insert the glass door between the hinge and reattach the hinge bolt 8 Please adjust the legs to level off the stove by adjusting the trim screws A from the baseplate ...

Страница 9: ...stones can be loaded in the outer edges where the stones are not in touch with the heating surfaces Fill the space between the mesh frame and the furnace with stones carefully one stone at a time The first 8 11 inches 20 30 cm from the floor are the most crucial ones while setting the stones into the heater Then the mesh takes its final round form The mesh and the furnace intermediate space must b...

Страница 10: ... 2 Adjust the connection chimney pipe and the upper mesh in the connection point of the chimney picture 1 and 2 3 Pile the stones to the lower part of the stove The mesh should lie against the circular firetube The piling of stones in the space between the upper mesh frame and the chimney pipe should be is done one stone at a time When loading the stones try to cover the chimney pipe as well as po...

Страница 11: ...00 mm to have service space C From the chimney pipe loaded with stones and equipped with a mesh to the side 10 inches 250 mm From the chimney pipe loaded with stones and equipped with a mesh upward 20 inches 500 mm D From a chimney pipe without stones to the side 20 inches 500 mm From a chimney pipe without stones upward 39 5 inches 1000 mm 3 1 Reducing the safety distances 50 when using simple pr...

Страница 12: ...P a g e 11 IKI Wood burning stoves Instructions for installation and use IKI Wood burning stoves Finnish high quality craftsmanship 4 Dimensional drawings and Connection heights ...

Страница 13: ...176 423 ft 5 12 m3 352 lbs 160 kg 121 lbs 55 kg 45 3 inches 115 cm 18 9 inches 48 cm 19 7 inches 50 cm Original IKI 353 882 ft 10 25 m3 660 lbs 300 kg 154 lbs 70 kg 32 3 inches 82 cm 23 6 inches 60 cm 23 6 inches 60 cm Original IKI Plus 353 882 ft 10 25 m3 750 lbs 340 kg 165 lbs 75 kg 52 inches 132 cm 23 6 inches 60 cm 23 6 inches 60 cm The outer diameter of the stove s chimney pipe is 4 528 inche...

Страница 14: ... on the top of the woodpile for example with a lighter piece cardboard packages birch bark or chopped firewood Keep the draft in fully open position at that moment 5 There is a knob A in the stove hatch that allows you to regulate the draft The regulation is done by moving the knob to the right open and to the left shut 6 You can also regulate the draft by opening the ash box B under the furnace 7...

Страница 15: ...ard to the sauna room space level of insulation are there many log walls or a lot of stone surfaces 2 Is the ventilation correctly measured 3 Are there enough stones have they been loaded correctly 4 Check the condition and quality of the stones Olivine dolerite stones smaller than 10 cm in diameter The stones do not heat up enough 1 Are there enough stones Have they been loaded correctly 2 Check ...

Страница 16: ...he chimney pipe on the stove as seen in picture below This does not require any tools 3 Sweep the chimney using a bendable nylon brush DO NOT USE a metal brush It might damage the pipe from inside 4 Another option is to use an industrial vacuum cleaner to clean up the spiral 5 Finally spray or pour some water and or use the brush to clean up the detachable chimney pipe not the spiral Chimney door ...

Страница 17: ...a 100 mm pipe 50 100 mm above the stone pocket of the stove The flow out of the sauna is preferably between the lower and upper bench through a disc valve equipped with an adjustable grid on the wall The air valve can also be placed on the ceiling or on the wall up close to the ceiling opposite the stove The stove makes the air rotate inside the sauna room and the oxygen rich compensation air move...

Страница 18: ... Wood burning stoves Instructions for installation and use IKI Wood burning stoves Finnish high quality craftsmanship 11 Example pictures of a correct air ventilation Mechanical forced ventilation Natural ventilation ...

Страница 19: ...or one 1 year from the date of purchase The broken part of the corresponding replacement will be shipped free of charge to the seller or the buyer directly The manufacturer is not responsible for the failed component removal and installation of the new part of the costs The broken part must be sent to the manufacturer Contact the manufacturer of your contract of carriage number before you return t...

Страница 20: ...y the customer Ikikiuas Ltd reserves the right to recover the cost from the customer if the customer returns have been subject to or breach of the contract Customer will be charged a processing and shipping fee 11 Quality guarantee Ikikiuas Ltd guarantees the stainless steel components for private home usage for 10 years During the warranty period occurring raw material or manufacturing defects re...

Страница 21: ..._________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ __...

Страница 22: ..._________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ __...

Страница 23: ...P a g e 22 IKI Wood burning stoves Instructions for installation and use IKI Wood burning stoves Finnish high quality craftsmanship ...

Страница 24: ...P a g e 23 IKI Wood burning stoves Instructions for installation and use IKI Wood burning stoves Finnish high quality craftsmanship ...

Отзывы: