14. WARNING
– Do not use electrical appliances inside the food storage compartments of the appliance,
unless they are of the type recommended by the manufacturer.
Troubleshooting
1. Please note, if a power failure occurs due to disconnection of the power cord, or the off power button
has been pushed off during an ice making cycle, small ice chips may formed and lodge in the automatic
shovel causing it to jam. If this occurs, the ice chips may be removed by disconnecting the power cord
and gently pushing the shovel to the rear of the cabinet and removing the ice chips, then restarting.
2. Please restart the ice maker by pressing Stop and then Start. If the Ice shovel does not push the Ice
into the Ice collector after the formed Ice drops from the evaporator finger while at the same time the M
light is on, check to see if the water tray is horizontal or balanced. If not then adjust by pressing the Ice
shovel lightly with your finger. Then re-start the Ice maker.
The compressor works
abnormally with a
Buzzing noise
Reasons
The voltage is lower than recommended
Solutions
Stop the Ice maker and do not restart until the voltage is
normal.
Conditions for Ice making
Cycle are right but no ice
is made.
Reasons
Refrigerant leaks./ Sealed system is
blocked
Solutions
call for service
The lights of ice full and
add water come at in the
same time.
Water tray is
blocked by
ice cube.
Clear the ice cube under the ice shovel pull out the plug
and insert It again then press the
button, 3 minutes
later the machine will restart automatically.
Machine keeps
running,but the water is
warmer than the normal
water.
The
magnetic
valve is
broken.
Replace the magnetic valve.