Your Ikelite Digital Housing should be given the same care and attention

as your other photographic equipment. In addition to normal

maintenance, we recommend that the housing be returned to Ikelite

periodically to be checked and pressure tested.

-

Do Not

leave the camera and housing in direct sunlight for prolonged

periods. Heat may damage the camera.

-

Do Not

ship the camera in the housing.

- Before using the housing, always check the tightness of the 

set screw

in each control knob. Check each 

control gland

penetrating the housing

to make sure they are tight. There is a slight chance that either could

vibrate loose during travel.

- Keep the main housing o-ring clean and lightly lubricated. To lubricate,

remove the o-ring from the back. Put a small amount of lkelite lubricant

on your fingers. Pull the o-ring through your fingers to apply a 

thin

coating of lubricant. Only apply enough lubricant to make the o-ring feel

slick. 

Do Not stretch the o-ring

. This light coating of lubricant will help

to keep the o-ring from drying out and will help to show a dark sealing

line when the housing back is properly sealed.

- Keep the area where the o-ring fits and the sealing surface of the

housing clean.

- Rinse the housing exterior thoroughly in freshwater after each saltwater

use. Depress push buttons repeatedly in freshwater to eliminate trapped

saltwater. Dry with a soft cloth. Dry lens port to eliminate water spotting.

After several uses in saltwater, soak the housing exterior in a mild soap

solution; rinse and dry before storing. When storing the housing, remove

the back o-ring, lightly lubricate, and place in a plastic bag. Place the

plastic bag with o-ring inside the housing for safe keeping. 

- If removing a housing push button, 

Do Not

re-use the E-clip. Contact

Ikelite for replacement E-clips (part 0319.12).

- Leave lid snaps in the open position when not using the housing for

extended periods.

Housing Maintenance

19

Содержание TTL Underwater Housing 6171.10 Panasonic Lumix LX100

Страница 1: ...171 10 Panasonic Lumix LX100 Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Please refer to the...

Страница 2: ...shoe to Camera P 9 STEP 5 Attach Camera to Mounting Tray P 10 STEP 6 Attach the Aperture Ring Gear to Lens P 11 STEP 7 Installing Camera in Housing P 12 STEP 8 Closing the Housing P 12 STEP 9 Final Ho...

Страница 3: ...pect and immerse the empty housing completely in water before installing a camera If any fogging occurs or droplets of water enter the housing do not install a camera Clean the main housing o ring and...

Страница 4: ...TTL circuitry compatible with current model Ikelite DS strobes Built in Flash None Tray and Handle Weight 11 5 oz 327 g Main O Ring 0110 Housing Dimensions 7 x 6 x 6 in 18 x 15 x 15 cm including proje...

Страница 5: ...hutter Button Lens Port External Tray Mounts Lid Snap Filter Button ON OFF Housing controls are provided for all camera functions except the Diopter Adjustment Dial Aspect Selector Switch Front Contro...

Страница 6: ...Control Dial 15 Drive Mode DOWN 16 Fn1 Delete Button 17 DISP Display Button iA Button Parts of the Housing Back View Control Dial Note that a small section of the rubber disc is missing at the end of...

Страница 7: ...accessory package Note Tray and Handle may be attached before or after the camera is secured in the Housing We recommend attaching it immediately to avoid scratching table tops with the Tray Mounting...

Страница 8: ...iResolution to Standard or other preferred setting Set Red Eye Removal to Off Set Stabilizer based on your shooting habits and environment IN C MENU Set Shutter AF to ON and Half Press Release to OFF...

Страница 9: ...h Forward Lid Snap Lock Lift STEP 4 Attach Hotshoe to Camera ON Front Ikelite Panasonic DMC LX100 OFF Diagram A Hotshoe Connector Mounting Tray Housing Back O ring External Strobe Connector Waterproof...

Страница 10: ...ntrol Dial cut away Rotate control to match Diagram B below This allows for proper clearance when attaching the housing back to the housing front 10 Lumix L Tray Mounting Bolt Aperture Ring Bump out C...

Страница 11: ...white dot at the 12 o clock position gently slide the Aperture Ring Gear over the camera Aperture Ring The camera s Aperture Ring Bump outs go between the the Aperture Ring Gear foam strips The Gear i...

Страница 12: ...operly engaged and test their function STEP 7 Installing Camera in Housing STEP 8 Closing the Housing 1 Once the back is properly installed the o ring should touch the housing all the way around There...

Страница 13: ...even all the way around the housing Look through the clear plastic back at the o ring You should see a darkened area or solid black line where the o ring is compressed against the housing back If you...

Страница 14: ...ord Attaching a Sync Cord to the Housing Diagram E Page 15 14 The Housing Bulkhead Connector is designed to accept sync cords with Ikelite 5 pin connector fittings 1 Lightly lubricate the Sync Cord O...

Страница 15: ...andle as shown Diagram F When the Ikelite Arm is properly seated the Handle Push Button will return to its starting position Ikelite Arm Handle Push Button Housing Handle Attaching an Ikelite Strobe A...

Страница 16: ...or filters such as the UR Pro Filter replace some of the reds oranges and more natural tones that would otherwise be lost underwater Effective in relatively shallow sunny conditions and available for...

Страница 17: ...o combine power with wide angle coverage to adequately light your subjects The DS161 quality of light is exceptional due to a round flash tube and custom powder coated reflector designed specifically...

Страница 18: ...nt it is used to reduce friction Excessive lubricant can collect sand and dirt which may interfere with proper sealing CAUTION Never use spray lubricants as the propellant ingredient can cause the pla...

Страница 19: ...lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and will help to show a dark...

Страница 20: ...n If this does not correct the problem return the housing to Ikelite for maintenance If you are on a trip and unable to return the housing immediately a push button may be lubricated by pressing and h...

Страница 21: ...allen wrench required remove the knob If there is salt or dirt build up on the exposed control shaft clean the shaft Open the housing and gently slide the control shaft out of the control gland Clean...

Страница 22: ...hoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a co...

Страница 23: ...several times to distribute the lube Diagram G Page 20 If a larger gland style control is sticky grab the control knob pull it out and then push back in If still sticky see the Control Maintenance sec...

Страница 24: ...y of diving If moisture or water droplets are present around the controls or sealing areas return the housing to Ikelite for evaluation Clean the main housing o ring and sealing surface of the housing...

Страница 25: ...hing a color correcting filter to the camera lens Add an external strobe Move in closer to your subject when taking a picture Add an optional color correcting filter to the Housing Port Zoom Control A...

Страница 26: ...o other warranty expressed or implied applies to this Ikelite product Limited Warranty Customer Support Please read the troubleshooting section of this instruction manual before contacting Ikelite Cus...

Страница 27: ...number inside of the package Send postage paid to Ikelite Underwater Systems Attention Service Department 50 West 33 Street Indianapolis IN 46208 USA No reimbursements for postage paid will be issued...

Страница 28: ...est 33rd Street Indianapolis IN 46208 USA www ikelite com Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase 2014 Ikelite Underwater Systems...

Отзывы: