Control Maintenance

Ikelite controls are designed to provide years of reliable service with

minimal maintenance.

- Push button controls normally require no maintenance other than rinsing

in freshwater after saltwater use. Depress each push button in

freshwater several times to eliminate trapped saltwater. If a push button

control becomes difficult to push or if it sticks when depressed, soak the

housing in luke warm freshwater. After a few minutes, operate the push

button. If this does not correct the problem, return the housing to Ikelite

for maintenance. If you are on a trip and unable to return the housing

immediately, a push button may be lubricated by pressing and holding

the push button all the way in. Then, use your finger or other small

object to place a small amount of lube at the base of the shaft inside the

housing. Press and release the push button several times until the lube

is worked up into the o-ring.

- Some of the controls have long shafts. These controls can be pulled out,

exposing the shaft see diagrams B and C - page 14. 

To lubricate the control, gently pull on the knob until the stainless steel

shaft is exposed. Lightly lubricate the shaft, then move the shaft in and

out several times. This will lubricate the x-ring in the Ikelite control gland.

This should be done before using the housing after a prolonged storage

period, or once a week when the housing is in constant use.

- Some of the controls have a short shaft and cannot be pulled out

exposing the shaft for lubrication. In the unlikely event one of these

controls sticks or becomes difficult to operate, you can remove the

control from the housing and lubricate it, or return the housing to Ikelite

for maintenance. To remove the control, diagram B - page 14, loosen

the set screw in the knob (allen wrench required); remove the knob. If

there is salt or dirt build-up on the exposed control shaft, clean the shaft.

Open the housing and gently slide the control shaft out of the control

gland. Clean and lightly lubricate the shaft, including the end of the

shaft. 

Содержание 6148.28

Страница 1: ...s t r u c t i o n m a n u a l 6148 28 for Canon SX280 HS Lens Port Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive...

Страница 2: ...8 Closing the Housing P 8 Final Check P 8 Usage P 9 Turn Camera On P 9 Zoom Control lever type only P 9 Using the Camera s Built in Flash P 9 Diffuser and Deflector Installation and Use P 10 Entering...

Страница 3: ...ra Clean the housing main o ring and retest to make sure that it is watertight Refer to the Troubleshooting section page 16 Please read your Nikon camera manual thoroughly to have a full understanding...

Страница 4: ...12M and Compression to S Superfine Set Movie Quality to 1920 30 In MENU Shooting Settings Set AF Frame to Center and AF Frame Size to Normal Set Digital Zoom to Off and AF Point Zoom to Off Set Servo...

Страница 5: ...ower Button Lens Port External Tray Mounts Lid Snap Initial Camera Setup continued Set Flash to forced On Flash always fires Set Macro mode to On when shooting close up If the image is overexposed use...

Страница 6: ...T Button Parts of the Housing Back View 7 Flash Right Button 8 Control Dial 9 DISP Display Button 10 Single Erase 11 MENU Button 6 Control Dial Note A small section is cut away from the Control Dial r...

Страница 7: ...camera on the tray 5 Using a coin or screwdriver preferred secure the camera with the tray mounting bolt which threads into the camera s tripod socket Diagram A Opening the Housing Lid Snaps have a Lo...

Страница 8: ...lly check the seal again Closing the Housing 1 Place housing face down in your lap 2 Check to see that there is an o ring on the housing back that is clean and in its proper location 3 Guide the back...

Страница 9: ...we recommend using external Ikelite Substrobes Zoom Control lever type only After you have used the housing s zoom control it must be returned to the center position to disengage If the housing zoom c...

Страница 10: ...e Diffuser You can test this above water Deflector Use The Deflector should be installed when using a slave unit to trigger an external strobe The Deflector will block and redirect the camera s flash...

Страница 11: ...glass or acrylic in the lens port as a camera lens After use rinse and gently dry the outside lens port to avoid water spotting To clean use a mild soap solution or lens cleaner Do not rinse the insi...

Страница 12: ...pply a thin coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and wi...

Страница 13: ...e o ring Some of the controls have long shafts These controls can be pulled out exposing the shaft see diagrams B and C page 14 To lubricate the control gently pull on the knob until the stainless ste...

Страница 14: ...Lubricate end of shaft before reinserting into gland Diagram B Control Maintenance continued Slide the shaft back into the control gland and gently slide it back and forth a few times without fully re...

Страница 15: ...Do not shoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue wate...

Страница 16: ...in If still sticky see the Control Maintenance section pages 13 14 Return housing to Ikelite for routine maintenance Problem Solution Image is over underexposed or a corner of the image is dark Check...

Страница 17: ...re forming fog on the lens port Close the housing in an air conditioned room or vehicle or in front of an air conditioner The housing should not be in direct sunlight for an extended period of time Pu...

Страница 18: ...a installed and pressure test or take diving Return housing to Ikelite for routine maintenance Problem Solution Pictures are too blue or too green Use custom manual white balance if available Reset fo...

Страница 19: ...ombinations offset the slightly positive buoyancy of the housings Handles offer attachment points for external lighting systems External Strobes A separate external strobe adds color to restore the wa...

Страница 20: ...or Green Water The UR Pro underwater color correcting filter is designed to restore some of the warm colors filtered out by the water For available light use only Not recommended for use with an exte...

Страница 21: ...used that does not emit a pre flash set the EV controller to the non pre flash P position A full range of accessories is available to support your housing Please visit www ikelite com to see the most...

Страница 22: ...Defective products should be returned to Ikelite postage paid Ikelite will at its sole discretion repair or replace such products and will return to customer postage paid All other claims of any natu...

Страница 23: ...ng any service to ensure that all products perform as intended Evidence of purchase date must be provided to obtain warranty service No prior authorization is required You may return directly to us or...

Страница 24: ...st 33rd Street Indianapolis IN 46208 USA www ikelite com 6148 28_Canon_SX280HS_01 0813 Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase 201...

Отзывы: