8
PCS-400P Series Dome Installation & Setup Guide
Accessing the Address Switches:
1. Rotate the internal drive, making sure not to touch
the sensitive PCB, until the two address switches can
be seen through the internal cover.
2. The address switches can now be rotated using a
VPDOOÀDWVFUHZGULYHUWRWKHDSSURSULDWHVHWWLQJV
Safety Note!
Make sure the power supply is switched off before
removing the internal mechanism.
Removal of Internal Mechanism:
1. Un-screw the three M5 cap head screws in the lower
housing. The screws are captive and will not fall out of
the lower housing.
2. The internal mechanism will drop by approximately
5 mm. A safety plate in the upper housing will hold it
there.
3. Rotate the internal mechanism anti-clockwise to free
it from the safety plate.
4. The mechanism can now be lowered and the internal
power cable can be disconnected from the top of the
internal mechanism.
Address Switch Access
M5 Cap Head
Screws
Installation - W
all Mount Dome
Installation :: External / Internal Wall Mount Dome :: Address Switch Access
!
Access
Switches
Electrical Connections
The External / Internal Wall Mount Dome external con-
nections are via an Amphenol connector with 1 metre
FRPSRVLWHÀ\LQJOHDGFRPSULVLQJRIFRD[SRZHUSDLU
and RS-485 pair.
The lead should be connected to the boxed PSU that is
supplied with the Dome.
If the lead needs to be extended it should be kept to a
minimum and not exceed 25 m.
The lead connections are as follows:
Red wire:
24 V AC Live
Blue wire:
24 V AC Neutral
<HOORZZLUH
56µ$¶
*UHHQZLUH
56µ%¶
Coax screen:
BNC screen
Coax signal:
BNC centre pin
Содержание PCS-400P Series
Страница 1: ...PCS 400P Series Dome Installation Setup Guide ...
Страница 2: ......